3.2.2 Mounting RG-WS6008 on Workbench
In the absence of a 19-inch standard cabinet, install the wireless controller on a clean workbench. During the operation,
pay attention to the following items:
The workbench is firm and well-grounded.
The supplied plastic cushion is stuck to the small hole at the bottom of the wireless controller and a 10 cm clearance
is reserved for dissipation.
No weight is placed on the top of the wireless controller.
3.3
Installing Power Cable
RG-WS6008 supports AC (100 VAC to 240 VAC; 50/60 Hz). Make sure that your power supply meets the requirement.
See
Chapter 1
for details about the power module.
RG-WS6008 uses three-wire power cable. It is recommended to use single-phase three-wire power socket or
multi-functional microcomputer socket with neutral-point connector. The neutral-point needs to be grounded safely. Check
whether the power supply in your building is grounded properly.
Follow the following steps to install the power cable:
1)
Connect one end of the supplied power cable to the socket on the rear panel of the device and another to the AC
power socket.
2)
Check the power indicator on the front panel is on. If it is, it means that the power cable is correctly connected.
3.4 EMS & Secure Grounding
The ground required for EMC design includes shielding ground, filter ground, noise and interference suppression, and
level reference. All the above constitute the comprehensive grounding requirements. The grounding resistance should be
smaller than
1Ω. The RG-WS6008 wireless controller has a grounding pole on the rear panel, as shown in Figure 3-1.
Figure 3-1 RG-WS6008 Grounding