For the AC power supply system TN, single-phase three-core power socket with protective earthing conductors (PE)
should be adopted to effectively filter out interference from the power grid through the filtering circuit.
The grounding device of the access point must not be used as the grounding device of the electrical equipment or
anti-lightning grounding device. In addition, the grounding device of the access point must be deployed far away
from the grounding device of the electrical equipment and anti-lightning grounding device.
Keep the equipment away from high-power radio transmitter, radar transmitting station, and high-frequency
large-current device.
Measures must be taken to shield static electricity.
Requirements of Installation Tools
Table 2-4 List of Installation Tools
Common Tools
Phillips screwdriver, flathead screwdriver, related electric cables and optical cables, bolts, diagonal
pliers, straps
Special Tools
Anti-static tools
Meters
Multimeter
The tool kit is customer-supplied.