Ruideng Technology Co. Ltd.

 

- 4 - 

 

button to display *.**A

**.*P

**.*V followed by recycling. 

 

3. Open or close load output 

 

    Press “ON/OFF” button, you can open or close load output

 

4, Set load default boot status (open or close status, Factory default close status

)

 

     

Press  and  hold  “ON/OFF”  button  to  set  load  default  boot  status  freely.  Press  and  hold 

“ON/OFF” button, if the LED will display “--ON”, as picture 4, the load will open output when 
power on next time; If the LED display”-OFF”, as picture 5 show, 
the  LED  will  display  current  value  flashing  at  last  shutdown 
when power on next time, then press “ON/OFF” button to open 
output.   

5, Set the load output recovery

 

mode after protection 

removed

.

 

Press and hold “SET” button to set output recovery

 

mode after 

protection 

removed. 

Press and hold “SET” button

, if the LED will 

display  “--ON”,  as  picture  4,  and  the  protection  was  removed, 
the load will recover to work; If the LED display”-OFF”, as picture 5 show, and the protection 
was removed, the LED still show protection status, then press “ON/OFF ‘button, the display 
will  display  present  setting  current  flashing,  then  press  “ON/OFF‘  button  again,  the  load 
recover to work.     

NOTE: 

 

Please check the output current of power bank carefully. The current of the general 

power bank is generally small, so adjust smaller current when the load was used.   

Application

 

Assist to measure 

Micro USB cable good or not 

 

Assist to measure 

Type

-

C cable good or not

 

Assist to measure output current capacity of charger good or not   

The usage of large batch ageing test at the charger factory     

 

 