RuiDeng LD25 Скачать руководство пользователя страница 3

Ruideng Technology Co. Ltd.

 

- 3 - 

 

A.

 

Micro USB port

MAX current 2A

 

B.

 

USB male port (widened power wire

MAX current 4A

 

C.

 

Type

-

C port

MAX current 4A

 

D.

 

All aluminum heat sink

 

E.

 

Intelligent temperature control fan

 

F.

 

4 Bit LED tube 

 

G.

 

Precision multiloop adjustable potentiometer

 

H.

 

“SET” button

press “SET” to switch display 

status

, Press and hold the button to set the load 

output recovery

 

mode after protection 

removed

.   

 

I.

 

“ON/OFF” button: press the button to open or close output. Press and hold the button to set 
the boot default 

status

 of open or close. 

 

 

Function Introduction: 

 

a. Protection function: 

 

OVP (over

-

voltage protection): there is OVP at 25

-

30V; it will 

be damaged 

permanently over 30V.at OVP, LED show OVP, 

as picture 1 show) 

OTP(over

-

temperature  protection):  load  temperature  is  over   

80

, the LED show OTP, as picture 2 show. 

 

OPP(over

-

power protection): the power is over 25W, the LED 

show OPP, as picture 3 show.

 

b. Set output recovery

 

mode after load entering protection 

status

manual or automatic

 

c.  View  the  voltage  value,  current  value  and  power  value  of  the 
load.   

 

d. 

Intelligent temperature control fan. When the power is over 10W or the temperature is over 

40

, the fan will start. 

 

e. 

Precision  multiloop  adjustable  potentiometer:  you  can  adjust  the  current  precisely,  upto 

0.01A. so you don’t need to adjust a big current mistakenly to damage the power supply. 

So 

the power supply will not be damaged due to mistakenly adjustment 

f. you can set default boot status freely, open or close. 

 

  Operation Instruction 

 

The  load  is  powered  at  the  range  of  4

-

25.0

V (the input polarity cannot be reversed, otherwise 

the  product  is  permanently  damaged  and  cannot  be  repaired),  the  LED  will  be  flashing  to 
remind  current  setting  value,  waiting  for  output.  Press  ON/OFF  button,  open  output  to  start 
work.   
1. Adjust output current value.   
   

Turning the rotary control clockwise increases the value and anticlockwise decreases the value. 

According to the  needs of  the situation, the potentiometer can realize coarse adjustment or 
fine adjustment. The fine adjustment can be accurate to 0.01A. 
2, Adjust LED display status 

Press “SET” to adjust the LED display status, default display output current value. 

Press “SET” 

Отзывы: