Push
“
Z/U
”
key to move the green block to the anticipant item, and when the green block is on
“
enable
”
items, push
“
Enter
”
key to enable or disable the item, when enabled, the small diamonds
is green, and when disabled, the small diamonds is grey. When the green block is on the
“
Set origin
”
item or the
“
Next origin
”
item, push the
“
X+-
“
keys to select the value.
Pay attention to if when the green block is on the
“
Set origin
”
item, push the
“
X+-
“
keys to select
a value, then,
“
Enter
”
key must be pushed to valid the change, or, the change is invalid.
Each item introduced as below:
Multiple Origins Enable:
“
Yes
”
or
“
No
”
can be selected. If you select
“
No
”
, the system will use
the single-origin logic. You can press the
“
Origin
”
key and set the origin, and only this origin can
become valid. If you select
“
Yes
”
, the system will use the multiple- origin logic and the
“
Origin
”
key on the keyboard become invalid. In such a case, the parameter of each origin must be set in the
menu as follows.
Origin Enable1/2/3/4: after the multiple-origin logic is enabled, the four origins can independently be
prohibited and enabled.
Set Origin 1/2/3/4: after the multiple- origin logic is enabled, you can stop the cursor at
“
Set as
Origin 1/2/3/4
”
. Press the
“
Enter
”
key on the keyboard and the system will take the coordinate
figures of current X/Y axles as the corresponding ones to the origin 1/2/3/4.
Next Origin: there are such five digits as 0~4 for option, which are the origins to be used for the next
figure. Origin 0 means the origin set by the
“
Origin
”
key on the panel in the single- origin logic. 1~4
means the serial number of the origins in the multiple- origin logic. Next origin can be modified to
any one of origin 1~4, so as to control the start location of next work (the premise is that the origin is
enabled), but it can
’
t be modified to origin 0.
Once the multiple- origin logic is selected and if the serial number of
the next origin is 1 and four origins are enabled, when the memory file
function is started or the processing file is uploaded into the PC and this
file selects “Take the Original Origin as current Origin”, the work started
for each time will use different origins. The rotation order of origin is
1->2->3->4->1->2…….
8.3.7 Set Fact Para
After the
“
Set Fact Para
”
is selected and the Enter key pressed, the interface will show the specific
password to be entered when set as default parameter.