![Ruida Technology RDC6445G Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/ruida-technology/rdc6445g/rdc6445g_manual_1499556048.webp)
RDC6445G/S Control System manual
SHENZHEN RUIDA TECHNOLOGY
41
When the "Select Block" stops on the "Start origin" entry, press the
<Enter>
key to enter the
modification, press the "Up/Down" key to modify, after the modification, press the
<Enter>
key, the
parameters automatically take effect, and press the
<Esc>
key to return to the menu interface.
Each item introduced as below:
Multiple Origins Enable:
“
Yes
”
or
“
No
”
can be selected. If you select
“
No
”
, the system
will use the single-origin logic. You can press the
<Origin>
key and set the origin, and only this
origin can become valid. If you select
“
Yes
”
, the system will use the multiple- origin logic and the
<Origin>
key on the keyboard become invalid. In such a case, the parameter of each origin must
be set in the menu as follows.
Origin Enable1/2/3/4:
after the multiple-origin logic is enabled, the four origins can
independently be prohibited and enabled.
Start Origin:
there are such five digits as 0~4 for option, which are the origins to be
used for the next figure. Origin 0 means the origin set by the
<Origin>
key on the panel in the
single- origin logic. 1~4 means the serial number of the origins in the multiple- origin logic. Start
origin can be modified to any one of origin 1~4, so as to control the start location of next work
(the premise is that the origin is enabled), but it can
’
t be modified to origin 0.
Once the multiple- origin logic is selected and if the serial number of
the next origin is 1 and four origins are enabled, when the memory
file function is started or the processing file is uploaded into the PC
and this file selects “Take the Original Origin as current Origin”, the
work started for each time will use different origins. The rotation order
of origin is 1->2->3->4->1->2…….
8.5.4 Backup parameters
In the menu interface, select the "Backup Factory Parameters" entry, press the
<Enter>
button
and then pop up the password input interface. The password input operation refers to Section 8.9. If
the password is input correctly, the system will backup all the current user parameters and factory
parameters. Interface prompt "Backup parameter is successful".
After the manufacturer regulates all parameters of the machine well
(including all manufacturer parameters and user parameters), this
function can be used to store the well-regulated parameters to help
Prompt
Prompt
Содержание RDC6445G
Страница 28: ...RDC6445G S Control System manual SHENZHEN RUIDA TECHNOLOGY 21 5 2 Examples of Glass tube Laser Power ...
Страница 29: ...RDC6445G S Control System manual SHENZHEN RUIDA TECHNOLOGY 22 5 3 Examples of RF Laser ...
Страница 32: ...RDC6445G S Control System manual SHENZHEN RUIDA TECHNOLOGY 25 6 2 Examples of Motor Driver Connection ...