background image

RUGGEDCOM RS900L

Installation Guide

Chapter 3

Communication Ports

EoVDSL Ports

15

2

1

Figure 10: MTRJ Port

1.

 Tx Connector   

 

2.

 Rx Connector

2

1

Figure 11: LC Port

1.

 Tx Connector   

 

2.

 Rx Connector

2

1

Figure 12: SC Port

1.

 Tx Connector   

 

2.

 Rx Connector

2

1

Figure 13: ST Port

1.

 Tx Connector   

 

2.

 Rx Connector

For specifications on the available fiber optic Ethernet ports, refer to 

Section 4.4, “Fiber Optic Ethernet Port

Specifications”

.

Section 3.3

EoVDSL Ports

Ethernet over VDSL (EoVDSL) ports operate in pairs with one device configured as the Master and the other as

the Slave. In VDSL (Very-high-bit-rate Digital Subscriber Line), the terms Central Office (CO) or Line Termination

(LT) are used interchangeably for the Master and the terms Customer Premise Equipment (CPE) or Network

Termination (NT) are used interchangeably for the Slave. The Master device dictates the line configuration

settings to the Slave so all EoVDSL configuration is done on the Master. Data flowing from the Master to the

Slave is designated 

downstream

 while data flowing from the Slave to the Master is designated 

upstream

.

Siemens offers two flavors of VDSL: Universal EoVDSL and Long-Reach EoVDSL. Universal EoVDSL ports are

Master/Slave selectable and offer symmetric data rates up to 35 Mbps with distances up to 2.5 km (1.6 mi). Long-

Reach EoVDSL ports are fixed as either Master or Slave but offer asymmetric data rates up to 40 Mbps with

distances up to 5 km (3.1 mi).
The Universal and Long-Reach EoVDSL ports are physically indistinguishable from each other. However, the port

type can be determined either from the order code or through ROS.
EoVDSL ports can be connected using RJ11 male connectors. Each EoVDSL port has a 

Link/Act

 LED and a

Master

 LED. On devices with Universal EoVDSL ports, the 

Master

 LED can be toggled on or off depending on

whether the port is set to be a Master or Slave. On devices with Long-Reach EoVDSL ports, the 

Master

 LED will

be on all the time if the device is set to be the Master, or off if the device is set to be the Slave.

Status LED

State

Description

Green (Solid)

The device is in Master mode.

Master

Off

The device is in Slave mode.

Green (Solid)

Link established

Link/Act

Green (Blinking)

Link activity

Содержание RuggedVDSL RS900L

Страница 1: ...RUGGEDCOM RS900L Installation Guide 10 2013 Preface Introduction 1 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Dimension Drawings 5 Certification 6...

Страница 2: ...this in mind Siemens products and solutions undergo continuous development Siemens recommends strongly that you regularly check for product updates For the secure operation of Siemens products and so...

Страница 3: ...the Device on a DIN Rail 6 2 1 2 Mounting the Device to a Panel 6 2 2 Connecting Power 7 2 2 1 Connecting High AC DC Power 8 2 2 2 Connecting Low DC Power 9 2 3 Connecting the Failsafe Alarm Relay 10...

Страница 4: ...Port Specifications 20 4 4 Fiber Optic Ethernet Port Specifications 20 4 5 Operating Environment 21 4 6 Mechanical Specifications 21 Chapter 5 Dimension Drawings 23 Chapter 6 Certification 25 6 1 Age...

Страница 5: ...ntly hazardous situations that if not avoided will result in death or serious injury WARNING WARNING alerts describe hazardous situations that if not avoided may result in serious injury and or equipm...

Страница 6: ...ge and expertise to understand the various technologies associated with critical communications network infrastructure technologies Siemens unique mix of IT Telecommunications expertise combined with...

Страница 7: ...ng and a galvanized steel enclosure allows the RS900L to be placed in almost any location The RS900L is packaged in a compact galvanized steel enclosure that allows either DIN or panel mounting for ef...

Страница 8: ...n Class 1 Division 2 40 to 85 C 40 to 185 F operating temperature no fans 20 AWG galvanized steel enclosure DIN or panel mounting options provide secure mechanical reliability Conformal coated printed...

Страница 9: ...erial Console Port Power Indicator LEDs The power indicator LED illuminates when power is being supplied to the device Alarm Indicator LED The alarm indicator LED illuminates when an alarm condition e...

Страница 10: ...RUGGEDCOM RS900L Installation Guide Chapter 1 Introduction Ports Controls and Indicator LEDs 4...

Страница 11: ...oid Changes or modifications not expressly approved by Siemens AG could invalidate specifications test results and agency approvals and void the user s authority to operate the equipment IMPORTANT Thi...

Страница 12: ...he device to a DIN rail do the following 1 Align the slot in the bracket with the DIN rail 1 1 2 Figure 2 DIN Rail Mounting 1 DIN Rail 2 DIN Rail Bracket 2 Pull the release on the bracket down and sli...

Страница 13: ...t breaker must be installed Equipment must be installed according to applicable local wiring codes and standards All line to ground transient energy is shunted to the Surge Ground terminal In cases wh...

Страница 14: ...wing CAUTION Electrical hazard risk of damage to equipment Do not connect AC power cables to terminals for DC power Damage to the power supply may occur CAUTION Electrical hazard risk of damage to equ...

Страница 15: ...r all surge and transient suppression circuitry internal to the unit 4 Connect the ground terminal on the power source to the chassis ground terminal on the device Section 2 2 2 Connecting Low DC Powe...

Страница 16: ...on circuitry internal to the unit 4 Connect the ground terminal on the power source to the chassis ground terminal on the device Section 2 3 Connecting the Failsafe Alarm Relay The failsafe relay can...

Страница 17: ...r terminal directly to the serial console port to access the boot time control and ROS console interface IMPORTANT The serial console port is intended to be used only as temporary connections during i...

Страница 18: ...ng of any length for critical real time substation automation applications All copper Ethernet ports on RUGGEDCOM products include transient suppression circuitry to protect against damage from electr...

Страница 19: ...0L chassis 1 2 3 Figure 8 Port Assignment 1 Ports 1 to 6 2 Ports 7 to 8 3 Port 9 Port Type 1 to 6 Fast Ethernet Ports 10 100Base TX 7 to 8 Fast Ethernet Ports 10 100Base TX or 10 100Base FX 9 EoVDSL P...

Страница 20: ...Yellow Solid Link established Yellow Blinking Link activity Link Off No link detected The following is the pin out for the RJ45 male connectors 1 8 Figure 9 RJ45 Ethernet Port Pin Configuration Pin N...

Страница 21: ...d downstream while data flowing from the Slave to the Master is designated upstream Siemens offers two flavors of VDSL Universal EoVDSL and Long Reach EoVDSL Universal EoVDSL ports are Master Slave se...

Страница 22: ...lowing Twisted pairs are an effective way of reducing both magnetic and capacitive interference because they reduce the magnetic loop area to nearly zero and maintain a consistent distribution of capa...

Страница 23: ...er of the reduced SNR By configuring the Rescan Mode parameter in ROS the user can control at which point the scan process will be restarted when the line conditions degrade If Link only is selected t...

Страница 24: ...150 The following performance is typical with Long Reach EoVDSL ports Distance km Distance feet Downstream Master to Slave Mbps Upstream Slave to Master Mbps Time to Achieve Port Up in Auto Mode Seco...

Страница 25: ...tion 4 6 Mechanical Specifications Section 4 1 Power Supply Specifications Input Range Power Supply Type Minimum Maximum Internal Fuse Rating ab Isolation Maximum Power Consumption c 88 VDC 300 VDC 4...

Страница 26: ...in each product when assembled and configured at the factory Refer to the ROS User Guide for the RS900L for information on how to obtain the factory configuration data NOTE All optical power numbers a...

Страница 27: ...1310 9 125 5 0 34 3 50 29 C9 SM SC 1310 9 125 5 0 37 0 90 42 Section 4 5 Operating Environment Parameter Range Comments Ambient Operating Temperature 40 to 85 C 40 to 185 F Measured from a 30 cm 12 i...

Страница 28: ...RUGGEDCOM RS900L Installation Guide Chapter 4 Technical Specifications Mechanical Specifications 22...

Страница 29: ...M RS900L Installation Guide Chapter 5 Dimension Drawings 23 Dimension Drawings NOTE All dimensions are in millimeters unless otherwise stated 187 96 168 66 7 87 65 13 116 59 99 10 Figure 15 Overall Di...

Страница 30: ...Chapter 5 Dimension Drawings RUGGEDCOM RS900L Installation Guide 24 13 64 134 09 101 60 11 176 183 89 83 82 120 65 78 74 194 06 Figure 16 Panel and DIN Rail Mount Dimensions...

Страница 31: ...FCC FCC Part 15 Class A Approved FDA CDRH 21 CFR Chapter I Sub chapter J Approved Section 6 2 FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital d...

Страница 32: ...r ports 4 kV line to earth 2 kV line to line 4 Signal ports 10 V 3 DC Power ports 10 V 3 AC Power ports 10 V 3 IEC 61000 4 6 Induced Conducted RFI Earth ground ports 10 V 3 IEC 61000 4 8 Magnetic Fiel...

Страница 33: ...vels Enclosure Contact 8 kV C37 90 3 9 ESD Enclosure Air 15 kV C37 90 2 8 Radiated RFI Enclosure ports 35 V m Signal ports 4 kV 2 5 kHz DC Power ports 4 kV AC Power ports 4 kV Fast Transient Earth gro...

Страница 34: ...de 28 EMI and Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 non condensing 55 C 131 F 6 cycles IEC 60255 21 1 Vibration 2 g...

Отзывы: