2.3 HIPOT (Dielectric Strength) Testing
Units which are to be “HIPOT” tested in the field must have the braided ground cable(s)
disconnected as shown in Figure 2.4 during the HIPOT test. This is required in order to
prevent the transient/surge suppression circuitry, which is connected to Surge Ground,
from being activated during the HIPOT test.
Braided Cable
Disconnect Braided Cable during
HIPOT (dielectric strength) testing!
HIPOT (Dielectric Strength) Testing
Figure 10: HIPOT (Dielectric Strength) Testing