23. WAN
ROX™ v2.2 User Guide
262
RuggedBackbone™ RX1500
the format of the data signal. The CSU part of the DSU/CSU manages electrical levels and isolation, and
provides loopback to the TELCO. A RuggedCom DDS port provides an integrated DTE, DSU, and CSU.
23.4.1. DDS Configuration
To configure DDS, you must first enable the WAN interface supporting DDS. See
“Enabling the DDS WAN Interface”
Under /interface/wan{wan slot and port}/dds you can configure the following:
Section 23.4.1.2, “Setting DDS Parameters”
.
• set the DDS PPP connection parameters. See
Section 23.4.1.3, “Setting DDS PPP Connection
• set the DDS frame relay and DLCI parameters. See
Section 23.4.1.4, “Setting DDS Frame Relay
Under interfaces/wan, you can also:
• view and clear DDS statistics. See
Section 23.4.2, “Viewing and Clearing DDS Statistics”
• perform a DDS loopback test. See
Section 23.4.1.5, “Performing a DDS Loopback Test”
23.4.1.1. Enabling the DDS WAN Interface
Before setting DDS parameters, you must first enable the WAN interface supporting DDS.
To enable the WAN DDS interface:
• In edit mode, navigate to /interface/wan{wan slot and port}.
• On the Enable Wan Interface form, select Enabled.
Figure 23.37. Enable Wan Interface form
• Commit the changes.
23.4.1.2. Setting DDS Parameters
To set DDS parameters, enter edit mode and navigate to /interface/wan{wan slot and port}/dds/
ddsparams.