DodgeAttack Order and Installation Manual:
Installation
DodgeAttack
–
Section 3 - Installation
© Rugged Interactive
20
21
Adjusting the Sensitivity
Notes:
• A small flat-bladed screwdriver is required.
• Do not over tighten, this can damage the sensors, a maximum of a quarter turn in the appropriate
direction should be made each time before retesting.
The sensitivity should be checked and if necessary adjusted after installation of the targets. Each target has
its own sensor, so each one should be checked.
To adjust the sensitivity, locate the silver plate on the reverse of the targets, as mentioned in section 3.4,
this should have remained clear of obstructions. There will be a hole in the silver plate, this contains a
screw as can be seen in
Figure 3.4.4
. Using a small flat-bladed screwdriver turn the screw in the desired
direction, clockwise to increase the sensitivity, Anti-clockwise to decrease. Turn a quarter turn before
retesting the sensitivity and repeat if required.
Do not over tighten the screw, this can damage the sensor.
Figure 3.4.4: Location to adjust sensitivity