Read this manual before installing the CardioWall Pro-X Elite.
Installation Guidelines:
▪
Complete the
Site Survey
form prior to delivery and/or installation.
▪
Send a completed
Installation Checklist
after any installation back to Rugged Interactive.
▪
A typical installation should take 2 people about 2 hours.
▪
The Pro-X is very heavy. Please ensure you have suitable equipment and/or manpower on site.
Ensure you observe correct manual handling techniques whilst moving and installing the Pro-X.
▪
The ground surface where the CardioWall Pro-X will be installed must be flat and level. Ground area
must be at least that of the Pro-X footprint (refer to System Specifications).
▪
A suitable electricity supply should be available within 1500 mm of the Pro-X (110 - 230V 13A).
▪
No obstructions or protrusions in the installation area: e.g. pipes, cables and wiring conduits.
▪
Avoid trapped and/or pinched cables. Use good practice when running data cables.
▪
To prevent electric shock, keep all electric components away from contact with water.
▪
IMPORTANT: Take anti-static precautions.
Fixings:
▪
The manufacturer will supply fixings.
▪
All fixings must be tight and secure.
Required Tools and Consumables:
▪
A small electrical-type flat-bladed screwdriver to unclip the CAT5 connectors from the pods.
▪
Cleaning cloth and gentle cleaning spray.
Operating Environment:
▪
Area clear in front of each CardioWall Pro-X: 2000 mm minimum.
▪
Keep out of direct sunlight; bright sunlight can affect the LED pod sensors.
▪
Keep indoors and dry.
▪
Optimum ambient temperature: 5°C to 30°C. Avoid extreme fluctuations of temperature.
Other Recommendations:
▪
Instruction / training carried out by an appropriate instructor to all new users.
▪
A waiting / spectating area positioned nearby is advised.
▪
A leaderboard is highly recommended.
IF YOU ARE IN ANY DOUBT, CALL RUGGED INTERACTIVE DIRECTLY ON +44 (0) 1726 833 882.