background image

Copyright © 2014 Ruckus Wireless, Inc.
Published April 2014, Part Number 800-70604-001 Rev A

Page 2 of 4

S

TEP

 1: C

ONNECTING

 

AND

 S

EALING

 

THE

 RJ-45 

C

ABLE

The AP uses one RJ-45 cable for Power over Ethernet (PoE). 
Connect and seal the cable using the M25 data cable gland (B in 
Figure 1).

1

Feed the end of the RJ-45 cable through the sealing nut (D in 
Figure 2), rubber sealing insert (C in Figure 2), clamping ring 
assembly (B in Figure 2) and cable gland base (A in Figure 2).

Figure 2:

RJ-45 cable and cable gland assembly

2

Use a wide flat-blade screwdriver to remove the blanking cap 
from the AP.

3

Connect the cable to the Ethernet port in the AP. 

4

Tighten the cable gland base into the AP chassis to 7 N.m or 
62 in-lbs.

5

Wrap the clamping ring assembly around the rubber sealing 
insert. Make sure that the clamping ring assembly fully 
encloses the rubber sealing insert.

6

Seat the clamping ring assembly and rubber sealing insert in 
the cable gland base.

7

Hand-tighten the sealing nut. 

8

Continue with 

Step 2a: Attaching the Hanger Mount to a Flat 

Surface

 or 

Step 2b: Attaching the Hanger Mount to a Metal 

Pole

.

S

TEP

 2

A

: A

TTACHING

 

THE

 H

ANGER

 M

OUNT

 

TO

 

A

 

F

LAT

 S

URFACE

1

Hold the hanger mount (D in Figure 1) at the location on the 
mounting surface where you want to mount the AP. Use the 
holes on the hanger mount as a template to mark the 
locations of the mounting holes.

2

Remove the hanger mount from the mounting surface.

3

Drill holes required for the customer-supplied mounting 
hardware.

4

Attach the hanger mount to the flat surface using the 
mounting hardware. 

5

Using the mounting hardware instructions, tighten the 
hardware to secure the hanger mount.

Figure 3:

Hanger mount on a flat surface 

NOTE:

 

Hanger mount shown attached vertically to allow AP 

elevation adjustments. Attach the hanger mount vertically to allow 
AP azimuth adjustments.

6

Continue with 

Step 3: Assembling the AP Mounting Bracket 

and the AP

.

S

TEP

 2

B

: A

TTACHING

 

THE

 H

ANGER

 M

OUNT

 

TO

 

A

 

M

ETAL

 P

OLE

1

Insert the open end of one steel clamp (H in Figure 1) into the 
upper two slots on the hanger mount (D in Figure 1).

2

Take the other steel clamp and insert it into the lower two slots 
on the hanger mount.

3

Use the clamps to attach the hanger mount to the pole (the 
clamps can be daisy-chained together to accommodate 
larger poles). Tighten the clamps to 3 N.m or 27 in-lbs, or per 
manufacturer’s specifications if the supplied clamps are not 
used.

Figure 4:

Hanger mount on a vertical pole

NOTE:

 

Hanger mount shown attached horizontally to allow AP 

azimuth adjustments. Attach the hanger mount vertically to allow 
AP elevation adjustments.

4

Continue with 

Step 3: Assembling the AP Mounting Bracket 

and the AP

.

A

B

C

D

Отзывы: