Copyright © 2014 Ruckus Wireless, Inc.
Published June 09 2014, Part Number 800-70553-001 Rev D
Page 3 of 4
S
TEP
4
A
: S
ECTOR
M
OUNTING
THE
AP
1
Place the AP mounting bracket attached to the AP on top of
the hanger mount so that the indexed teeth and screw holes
on both are aligned.
Figure 7:
Sector mounting
NOTE:
Hanger mount shown attached horizontally to allow AP
azimuth adjustments. Attach the hanger mount vertically to allow
AP elevation adjustments.
NOTE:
The safety cable and ground wire are not shown in Figure
7 and up for clarity.
2
Insert an M8 hex bolt with split and flat washers into the
vertical screw hole on the mounting bracket.
3
Finger tighten the hex bolt until it passes through the screw
hole on the hanger mount.
4
Adjust the orientation of the AP as required. Note the
preferred internal GPS antenna position.
NOTE:
For the GPS feature to operate, the unit must have a
mostly unobstructed view of the sky.
Figure 8:
Preferred sector-mount orientation for GPS operation
5
Using a 13mm wrench, tighten the M8 hex bolt to 13.6 N.m
(10 ft-lbs) so the mounting bracket is securely fastened to the
hanger mount.
6
Continue with
Step 5: Earth Grounding the AP
.
S
TEP
4B: D
OME
-D
OWN
M
OUNTING
THE
AP
1
Align one of the holes on the extension bracket (G in Figure 1)
with the hole on the hanger mount.
Figure 9:
Align the extension bracket hole with the hanger mount hole
2
Insert an M8 hex bolt with split and flat washers into hole and
finger tighten until the bolt passes through the screw hole on
the hanger mount.
Figure 10:
Finger-tightened hex bolt
3
Align the hole on the mounting bracket with the remaining
hole on the extension bracket.
4
Insert an M8 hex bolt into the hole and finger tighten until the
bolt passes through the extension bracket.
Figure 11:
Dome-down mounting
5
Adjust the azimuth and elevation of the AP as required. Note
the preferred internal GPS antenna position.
NOTE:
For the GPS feature to operate, the unit must have a
mostly unobstructed view of the sky.
Figure 12:
Preferred dome-down-orientation for GPS operation
6
Using a 13mm wrench, tighten the M8 hex bolts to 13.6 N.m
(10 ft-lbs) so the extension bracket is securely fastened to the
AP mounting bracket and the hanger mount.
7
Continue with
Step 5: Earth Grounding the AP
.
S
TEP
5: E
ARTH
G
ROUNDING
THE
AP
CAUTION:
Make sure that earth grounding is available and that it
meets local and national electrical codes. For additional lightning
protection, use lightning rods and lightning arrestors.
NOTE:
The color coding of ground wires varies by region. Before
completing this step, check your local wiring standards for
guidance.
•
Using the factory-supplied ground wire and ground screw,
connect a good earth ground to the AP chassis ground point
(A in Figure 13).
CAUTION:
The AP includes one 12mm stainless steel M6x1 earth
ground screw with split lock and flat washers. Make sure that any
replacement screw is no longer than 12mm. If a screw is longer
than 12mm, it can damage the AP chassis.
Figure 13:
Connect good earth ground to AP here
Congratulations! You have mounted your access point.
A