FIGURE 8 Attaching the mounting bracket to a vertical pole
4. Continue with
Mounting the Linkage Bracket to the U-
Joint Bracket
.
Mounting the Linkage Bracket to the U-Joint
Bracket
1. The linkage bracket attaches to the U-joint bracket using
an M8 bolt and washer set. The linkage bracket is
symmetrical, and either end can be attached to the U-joint
bracket.
NOTE: Make sure that linkage bracket is installed with
its serrated external-tooth lock washer on the inside of
the U-joint bracket flanges. This ensures that the
azimuth adjustment does not change.
2. Loosely assemble the linkage bracket (A), the U-joint
bracket (C), one serrated external-tooth lock washer (B),
and one M8 bolt and washer set (D).
FIGURE 9 Attaching the linkage bracket to the U-joint bracket
3. Set the azimuth required by the AP.
4. Tighten the M8 bolt to 13.6 N-m (10 ft-lbs).
5. Continue with
Attaching the AP Bracket to the Linkage
Bracket
.
Attaching the AP Bracket to the Linkage Bracket
Attach the AP bracket to the linkage bracket using the
included bolt, nut, lock washer, flat washer, serrated external-
tooth washer shown in the illustration below.
The AP bracket attaches to the linkage bracket using an M8
bolt and washer set. The linkage bracket is symmetrical, and
either end can be attached to the AP bracket.
NOTE: Make sure that linkage bracket is installed with its
serrated external-tooth lock washer on the inside of the AP
bracket flanges. This ensures that the elevation adjustment
does not change.
As described in
Mounting the Linkage Bracket to the U-
Joint Bracket
, loosely assemble the AP bracket to the
linkage bracket using the second serrated external-tooth
lock washer and the second M8 bolt and washer set.
FIGURE 10 Attach the linkage bracket to the AP bracket
Attaching the AP Bracket to the Access Point
1. Place the AP bracket onto the back side of the AP so that
the four larger screw holes on the bracket align with the
four screw holes on the AP. Make sure that the end of the
AP bracket with the hoisting loop is on the same side as
the AP PoE IN port.
FIGURE 11 Attaching the AP bracket to the AP
2. Use four 0.5-inch x 0.250-28 hex bolts with split lock and
flat washer sets to mount the AP bracket to the AP.
Tighten the bolts to 2.5-3.0 N.m or 22-27 in-lbs.
CAUTION!
Make sure that the screws are no longer
than 0.5 inch. If a screw is longer than 0.5 inch, it can
damage the AP chassis.
3. If required, suspend the AP by attaching a carabiner to
the hoisting loop on the AP bracket.
NOTE: This kit may include extra screws, nuts and
washers. You may use the extras where required.
4. Continue with
Set the Elevation and Tighten Elevation
Bolt
.
Set the Elevation and Tighten the Elevation Bolt
1. Set the elevation required by the AP.
2. Tighten the M8 bolt to 13.6 N-m (10 ft-lbs).
3. Continue with
Powering the AP with DC
.
Copyright
®
2017 Ruckus Wireless, Inc.
Page 3 of 4
Published September 2017, Part Number 800-71623-001 Rev A