FIGURE 3  Typical AP high-density narrow-sector coverage

Mounting Instructions

Connecting And Sealing the RJ-45 Cables

Connect and seal the RJ-45 cable(s) using the M25 data

cable glands shown in the Figure below.

WARNING! 

Do not use any PoE injector not tested and

approved by Ruckus Wireless to power the T310n Access

Point.

FIGURE 4  T310n LEDs and Ports

1. Feed the end of the cable through the sealing nut, rubber

O-ring, clamping ring assembly and cable gland base as

shown.

NOTE: Do not seat the clamping ring and rubber O-ring

into the gland body until the gland body has been

torqued to spec.

FIGURE 5  RJ-45 cable and cable gland assembly

2. Use a wide flat-blade screwdriver to remove the required

(PoE IN) blanking cap from the AP.

3. Connect the cable to the Ethernet port on the AP.
4. Tighten the cable gland base into the AP chassis to 7 N.m

or 62 in-lbs.

5. Wrap the clamping ring assembly around the rubber O-

ring. Make sure that the clamping ring assembly fully

encloses the rubber O-ring.

6. Seat the clamping ring assembly and rubber O-ring in the

cable gland base.

7. Hand-tighten the sealing nut.

Attaching the U-Joint Bracket to the Mounting

Bracket

1. Position the U-joint bracket on the mounting bracket.

NOTE: Mount the U-joint bracket in any direction on the

mounting bracket, preferably to allow AP azimuth

adjustments. Then the AP bracket allows AP elevation

adjustments.

FIGURE 6  U-joint bracket attached horizontally to the mounting bracket

2. Use four 1/4-28 bolt and washer sets (A) to mount the U-

joint bracket (B) to the mounting bracket (C). Tighten the

bolts to 9.5 N.m (7 ft-lbs).

3. Continue with 

Attaching the Mounting Bracket to a Flat

Surface

 or 

Attaching the Mounting Bracket to a Pole

.

Attaching the Mounting Bracket to a Flat Surface

1. Place the mounting bracket at the location on the flat

surface where you want to mount the AP. Use the holes

on the mounting bracket as a template to mark the

locations of the mounting holes.

FIGURE 7  Mounting bracket flat surface holes

2. Remove the mounting bracket from the flat surface.
3. Drill holes required for the mounting hardware.

NOTE: The hardware required for mounting to a wall

are not included in the mounting kit.

4. Attach the mounting bracket to the flat surface using the

mounting hardware.

5. Using the mounting hardware instructions, tighten the

hardware to secure the mounting bracket.

6. Continue with 

Mounting the Linkage Bracket to the U-

Joint Bracket

.

Attaching the Mounting Bracket to a Pole

1. Insert the open end of one steel clamp into the upper two

slots on the mounting bracket.

2. Take the other steel clamp and insert it into the lower two

slots on the mounting bracket.

NOTE: The clamps can be daisy-chained together to

accommodate larger poles.

3. Use the clamps to attach the mounting bracket to the

pole. Tighten the clamps to 3 N.m or 27 in-lbs, or per

manufacturer’s specifications.

Copyright 

®

 2017 Ruckus Wireless, Inc.

Page 2 of 4

Published September 2017, Part Number 800-71623-001 Rev A

Содержание T310n

Страница 1: ...s Wireless products please check for the latest software and the release documentation Release Notes and other user documentation are available at http support ruckuswireless com documents Software upgrades are available at http support ruckuswireless com software Open source information is available at http opensource ruckuswireless com Software license and limited warranty information are availa...

Страница 2: ...FIGURE 6 U joint bracket attached horizontally to the mounting bracket 2 Use four 1 4 28 bolt and washer sets A to mount the U joint bracket B to the mounting bracket C Tighten the bolts to 9 5 N m 7 ft lbs 3 Continue with Attaching the Mounting Bracket to a Flat Surface or Attaching the Mounting Bracket to a Pole Attaching the Mounting Bracket to a Flat Surface 1 Place the mounting bracket at the...

Страница 3: ...al tooth lock washer on the inside of the AP bracket flanges This ensures that the elevation adjustment does not change As described in Mounting the Linkage Bracket to the U Joint Bracket loosely assemble the AP bracket to the linkage bracket using the second serrated external tooth lock washer and the second M8 bolt and washer set FIGURE 10 Attach the linkage bracket to the AP bracket Attaching t...

Страница 4: ...t any replacement screw is no longer than 9mm If a screw is longer than 9mm it can damage the AP chassis FIGURE 12 Connect good earth ground to AP here Congratulations You have mounted your T310n access point Installing a USB Dongle To install a USB dongle such as an IoT radio device such as BLE 802 15 4 Z wave or similar remove the two 3mm hex screws remove the cap and insert the dongle into the ...

Отзывы: