Mounting and Powering the SCG
Step 7: Attach the Mounting Ears to the Rail Assembly
SmartCell Gateway 200 Getting Started Guide for SmartZone 3.4, 800-71126-001 Rev A
27
Step 7: Attach the Mounting Ears to the Rail
Assembly
Attach the rack mounting ears (A) to each side of the server using the #10-32 x 3/
8 screws (B).
Figure 12. Attaching the mounting ears
Step 8: Slide the Rail Assembly into the Outer
Rails and Secure to the Rack
WARNING!
The SCG appliance is heavy (40 lbs/18.14kg). Two people should work
together to lift and slide the appliance into the rack. Ruckus Wireless strongly
recommends against one person attempting to perform this task alone.
1
Align the inner rails (attached to the server chassis) with the outer rail assemblies
(attached to the rack).
2
Engage the matching rails, and then slide the server chassis into the rack until
the two spring safety locks snap into position.
3
Press down the two spring safety locks (one on each side). See 1 in Figure 13.
4
Slide the server chassis all the way into the rack. See 2 in Figure 13.
5
Use the rack screws (#8-32 x 3/4) to secure the chassis and rack handles into
the rack. See 3 in Figure 13.