Figure 15:

Assembling the AC power connector

Two different-sized grommets are supplied in the AC connector assembly kit. Use the grommet that is 
appropriate to the diameter of the AC cable that you are using.

7

Mate the boot with the cable gland, and then hand-tighten to seal.

8

Connect the AC cord connector that you have assembled to the AC power socket on the AP.

9

Connect the AC cord to an AC power source. 

CAUTION:

 

If required, you can reset the AP to its factory default settings by pressing the reset button 

located inside the PoE OUT/RESET port. DO NOT DO THIS UNLESS SO INSTRUCTED. (Doing this resets 
the SC8800-S IP address to 192.168.0.1.)

NOTE:

 

After a reset, you can access the internal SC8800-S AP web interface using 

https://

192.168.0.1

. Your device must use any other address from 192.168.0.2 through 192.168.0.254, with 

subnet mask 255.255.255.0 and default gateway 192.168.0.1. The username is 

super

, and the password 

is 

sp-admin

. Refer to the ZoneFlex SmartCell SC8800-S Outdoor Access Point Installation Guide and the 

ZoneFlex Outdoor Access Point User Guide for information on configuring and operating the SC8800-S AP. 
Both documents are available at 

https://support.ruckuswireless.com

.

Congratulations! You have mounted the SC8800-S access point.

T

ROUBLESHOOTING

: R

EPLACING

 

THE

 AP F

USES

 (

ONLY

 

IF

 

REQUIRED

)

NOTE:

 

If the PWR LED does not turn on at all, one or both of the AC power supply fuses inside the 

SC8800-S chassis may have burned out. Replace them as follows:

1

Remove power from the SC8800-S. 

2

Open the SC8800-S cover and replace any burned-out 5A, 250V, slow-blow fuse(s), as required. 
Figure 16 shows the SC8800-S fuse locations.

Figure 16:

Fuse locations

3

Make sure that the gasket around the front cover is in its channel.

4

Loosely close the front cover of the SC8800-S.

5

Tighten the four front-cover captive screws in the order shown in Figure 17 to 1.7 N.m (15 in-lbs).

6

Retighten the four front-cover captive screws in the order shown to 2.3 N.m (20 in-lbs).

7

Retighten the four front-cover captive screws in the order shown to 2.8 N.m (25 in-lbs).

Figure 17:

Front cover screw-tightening pattern

8

Re-apply power to the SC8800-S. 

You have completed replacing the fuses in the SC8800-S. 

36mm or 1.42in (max)

9mm or 0.35in (max)

1

3

2

Earth Ground
Neutral/Return
Line/Hot
(not used)

1

3

2

Wire Stripping Drawn 
Actual Size (1:1)

2

3

4

1

Содержание SC8800-S

Страница 1: ...omer supplied earth ground wire 3 5mm2 or 10 12 AWG 1 2 13mm flat blade screwdriver or equivalent No 2 Phillips screwdriver Small flat blade screwdriver Torque wrench or torque screwdriver with sockets Long nose pliers Electrical wire stripping and terminal crimping pliers Pipe or pole OR a sturdy flat surface Electric drill with drill bits and customer supplied wall anchors flat washers and hex n...

Страница 2: ...g hardware instructions tighten the hardware to secure the main mounting bracket 6 Continue with Step 4 STEP 3B ATTACHING THE MAIN MOUNTING BRACKET TO A WOODEN POLE 1 Place the main mounting bracket at the location on the mounting surface where you want to mount the AP Use the square holes on the main mounting bracket as a template to mark the locations of the mounting holes Figure 5 Wooden pole m...

Страница 3: ...a loop on one end and a retaining washer on the eye end 1 Thread the safety cable around the main mounting bracket A and thread the eye end B through the loop end C Figure 12 Secured safety cable 2 Use one M6 bolt and washer set to attach the eye end of the safety cable A to a threaded boss on the back of the AP B Tighten the bolt to 9 5 N m 7 ft lbs Figure 13 Attaching the safety cable to the AP ...

Страница 4: ...ide and the ZoneFlex Outdoor Access Point User Guide for information on configuring and operating the SC8800 S AP Both documents are available at https support ruckuswireless com Congratulations You have mounted the SC8800 S access point TROUBLESHOOTING REPLACING THE AP FUSES ONLY IF REQUIRED NOTE If the PWR LED does not turn on at all one or both of the AC power supply fuses inside the SC8800 S c...

Отзывы: