background image

Copyright © 2014 Ruckus Wireless, Inc.
Published January 2014, Part Number 800-70548-001 Rev C

Page 1 of 4

SC8800-S Access Point

Mounting Guide

This 

Mounting Guide

 provides step-by-step instructions on how to 

field-install the Ruckus Wireless ZoneDirector SC8800-S access point 
(AP), part number 9x1-8800-xxxx.
For detailed information on planning the installation, pointing the 
internal GPS antenna, performing a site survey, preparing the 
SC8800-S at the depot, and shipping to the field, refer to the 

ZoneFlex 

SmartCell SC8800-S Outdoor Access Point Installation Guide

. For 

information on operating the SC8800-S, refer to the 

ZoneFlex Outdoor 

Access Point User Guide

. Both documents are available at 

https://

support.ruckuswireless.com

.

WARNING:

 

Only trained and qualified personnel should be allowed to 

install, replace, or service this equipment.

 

WARNING: 

Installation of this equipment must comply with local and 

national electrical codes.

 

CAUTION:

 

Make sure that you form a 80mm - 130mm (3”-5”) drip 

loop in any cable that is attached to the AP or the building. This will 
prevent water from running along the cable and entering the AP or the 
building where the cable terminates. 

CAUTION:

 

Be sure that grounding is available and that it meets local 

and national electrical codes. For additional lightning protection, use 
lightning rods and lightning arrestors.

 

CAUTION:

 

Make sure that proper lightning surge protection 

precautions are taken according to local electrical code.

 

WARNING:

 

Ruckus Wireless strongly recommends that you wear eye 

protection before mounting the SC8800-S.

T

HIS

 G

UIDE

 

IN

 O

THER

 L

ANGUAGES

请从以下网站获得该指南的简体中文版

 

https://support.ruckuswireless.com

.

Vous trouverez la version française de ce guide à l'adresse suivante 

https://support.ruckuswireless.com

.

こ の ガ イ ド の日本語版は 

https://support.ruckuswireless.com

 

で ご覧 く だ さ い。

 

가이드의

 

한국어

 

버전은

 

 

사이트

(

https://support.ruckuswireless.com

)

에서

 

확인하시기

 

바랍니다

.

Veja a versão em português (Brasil) deste guia em 

https://support.ruckuswireless.com.

Puede ver la versión en español (América Latina) de esta guía en 

https://support.ruckuswireless.com.

B

EFORE

 Y

OU

 B

EGIN

Before deploying your Ruckus Wireless SC8800-S, verify that all items 
listed in 

Package Contents

 are included in the package. If any item is 

damaged or missing, notify your authorized Ruckus Wireless sales 
representative. Also, make sure that you have the required hardware 
and tools. 

R

EQUIRED

 H

ARDWARE

 

AND

 T

OOLS

Customer-supplied outdoor-rated three-wire (1-2mm

2

 or 14-

18AWG) AC cable

Customer-supplied earth-ground wire (3-5mm

2

 or 10-12 AWG)

1/2” (13mm) flat-blade screwdriver or equivalent

No. 2 Phillips screwdriver

Small flat-blade screwdriver

Torque wrench or torque screwdriver with sockets

Long-nose pliers

Electrical wire stripping and terminal crimping pliers

Pipe or pole --OR-- a sturdy flat surface

Electric drill with drill bits and customer-supplied wall anchors, flat 
washers, and hex nuts for flat-surface mount

Two customer-supplied M16 (5/8”) carriage bolts for main 
mounting bracket on a wooden pole

Four customer-supplied 6mm (1/4“) bolts or screws for main 
mounting bracket --OR-- 
Four customer-supplied 14mm (1/2“) bolts or screws for main 
mounting bracket --OR-- 

Four factory-supplied 1/2” (12.7mm) wide stainless steel adjust-
able clamps, 2.5” (63.5mm) diameter, for main mounting bracket 
on smaller poles --OR-- 

Two 7/8” customer-supplied (22mm) wide stainless steel adjust-
able clamps for main mounting bracket on larger poles

Ruler

P

ACKAGE

 C

ONTENTS

A complete SC8800-S field installation package includes all of the 
items listed below:

SC8800-S Access Point (A in Figure 1), includes crimp-type earth-
ground ring terminal

Two M25 data cable glands (B in Figure 1)

One main mounting bracket (C in Figure 1)

One U-joint bracket (D in Figure 1)

Nine sets 12mm M6 x 1 hex bolt with lock and flat washers 
(E in Figure 1)

One hook bracket (F in Figure 1)

One set 70mm M8x1.25 hex bolt with spring lock and flat 
washers (G in Figure 1)

One AP attachment bracket (H in Figure 1)

Four SAE32 steel clamps, 2.5-inch diameter (I in Figure 1)

One AC power cable input end connector and cap 
(J in Figure 1)

One safety cable (K in Figure 1)

This 

Mounting Guide

 

Figure 1:

SC8800-S field-installation package contents

The field installation package can also include: 

Service Level Agreement/Limited Warranty Statement

Regulatory Statement

Registration card

Declaration of Conformity, if required

NOTE: 

This kit can include extra screws, nuts and washers. You may 

use the extras wherever required.

S

TEP

 1: C

ONNECTING

 

AND

 S

EALING

 

THE

 RJ-45 

C

ABLES

The SC8800-S may use zero, or one or two RJ-45 cables, one for 
Ethernet when configured as a Root AP (RAP), and one when the 
SC8800-S is supplying PoE out to a peripheral device, such as a small 
cell or micro cell radio. When the SC8800-S uses RJ-45 cables, 
connect and seal the cables using the M25 data cable glands (B in 
Figure 1).

1

Feed the end of the cable through the sealing nut, rubber O-ring, 
clamping ring assembly and cable gland base as shown in Figure 
2.

CAUTION!

THE MINIMUM SOFTWARE REVISION FOR 

THE SC8800-S IS ZONEFLEX (ZF) 9.6.1 OR LATER. 

DO NOT CONNECT THE SC8800-S TO A RUCKUS 

WIRELESS CONTROLLER WITH ZF 9.6.0 OR 

EARLIER.

F

G

H

E

A

C

B

D

I

J

K

Содержание SC8800-S

Страница 1: ...omer supplied earth ground wire 3 5mm2 or 10 12 AWG 1 2 13mm flat blade screwdriver or equivalent No 2 Phillips screwdriver Small flat blade screwdriver Torque wrench or torque screwdriver with sockets Long nose pliers Electrical wire stripping and terminal crimping pliers Pipe or pole OR a sturdy flat surface Electric drill with drill bits and customer supplied wall anchors flat washers and hex n...

Страница 2: ...g hardware instructions tighten the hardware to secure the main mounting bracket 6 Continue with Step 4 STEP 3B ATTACHING THE MAIN MOUNTING BRACKET TO A WOODEN POLE 1 Place the main mounting bracket at the location on the mounting surface where you want to mount the AP Use the square holes on the main mounting bracket as a template to mark the locations of the mounting holes Figure 5 Wooden pole m...

Страница 3: ...a loop on one end and a retaining washer on the eye end 1 Thread the safety cable around the main mounting bracket A and thread the eye end B through the loop end C Figure 12 Secured safety cable 2 Use one M6 bolt and washer set to attach the eye end of the safety cable A to a threaded boss on the back of the AP B Tighten the bolt to 9 5 N m 7 ft lbs Figure 13 Attaching the safety cable to the AP ...

Страница 4: ...ide and the ZoneFlex Outdoor Access Point User Guide for information on configuring and operating the SC8800 S AP Both documents are available at https support ruckuswireless com Congratulations You have mounted the SC8800 S access point TROUBLESHOOTING REPLACING THE AP FUSES ONLY IF REQUIRED NOTE If the PWR LED does not turn on at all one or both of the AC power supply fuses inside the SC8800 S c...

Отзывы: