Ruckus Wireless Fiber Node Скачать руководство пользователя страница 3

Copyright © 2013 Ruckus Wireless, Inc.

Page 3 of 4

Published November 2013, Part Number 800-70378-001 Rev C

S

TEP

 5: I

NSTALLING

 

THE

 F

IBER

 N

ODE

 

AND

/

OR

 

A

CCESS

 P

OINT

A. If you are mounting a Fiber Node, then continue with 

Step B.

 If you are mounting an AP, then continue with 

Step D.

B. Slide the FN enclosure and device mounting bracket 

assembly onto the dual-slide adapter plate, clean oil 
and grease off the screw threads, apply Loctite to the 
screw threads, and tighten the two captive screws (A) 
to 3.38 N.m (30 in-lbs).

C. If required, repeat 

Step 5: Installing the Fiber Node 

and/or Access Point

. When you have mounted the 

last of the APs and FNs, continue with 

Step 6: 

Installing the Fiber Optic Cable

.

D. Slide the AP enclosure and device mounting bracket 

assembly onto the dual-slide adapter plate, clean oil 
and grease off the screw threads, apply Loctite to the 
screw threads, and tighten the two captive screws 
(with captive springs) to 3.38 N.m (30 in-lbs).

E. If required, then repeat 

Step 5: Installing the Fiber 

Node and/or Access Point

. When you have mounted 

the last of the APs and FNs, continue with 

Step 6: 

Installing the Fiber Optic Cable

.

S

TEP

 6: I

NSTALLING

 

THE

 F

IBER

 O

PTIC

 C

ABLE

A. Open the fiber enclosure by loosening the four 

captive fasteners on the enclosure lid. 

B. Insert the fiber optic cable through the cable gland 

and prepare the fiber cable with the supplied shield 
bond connector. Install the shield bond connector per 
the manufacturer’s instructions (Scotchlok 4460-D\FO 
Shield Bond Connector). 

C. Attach the ground wire to the shield bond connector 

and then secure the connector to the fiber enclosure 
with wire ties.

D. Wind “out of service” fibers around the left fiber 

spool. Secure fibers to the enclosure with wire tie.

E. Wind the “in service” fiber around the right fiber 

spool and the insert fiber connector into mating 
sleeve.

F. Ensure the weather seal gasket on the enclosure lid is 

not damaged or out of position. Close lid and torque 
the four captive screws to 3.38 N.m (30 in-lbs). 

S

TEP

 7: I

NSTALLING

 

THE

 M

EDIA

 C

ONVERTER

A. Open the fiber enclosure by loosening the four 

captive fasteners on the enclosure lid. 

B. Make sure that the PoE Splitter is set to 12V (A).

C. Place the media converter unit into the fiber 

enclosure. Secure the unit to the enclosure by 
torquing the six M3 captive screws to 0.8 N.m 
(7 in-lbs).

A

(with M25 gland)

(with FOTC)

A

Отзывы: