Ruby 025 FDA Скачать руководство пользователя страница 14

14

4.0 Pump Disassembly

Step 1    

Remove the discharge manifold by untying

the screws in X formulation

Step 2

Remove the balls and the seats. Reverse

the pump and remove the suction manifold

with the same way  

Step 3

Untie one of the two housings, by untying the

screws gradually and cyclically.

Step 4

Detach  the  diaphragm  from  the  central

block by hand and untie it with a left rotation.

Step 5

Untie  the  opposite  housing  and  pull  the

diaphragm along with the shaft outwards.

Remove the diaphragm from the shaft

Step 1 - Step 2

We remove the safeties (step 1) and push

from the one side the air control unit to-

wards the outer part (step 2)

4.1 Air control valve disassembling  

Содержание 025 FDA

Страница 1: ...2G x h IIB T4 Gb II 2D x h IIIB 135 C Db Baseefa15ATEX13DR RN3 Installation Operation and Maintenance AirOperatedDiaphragmPumps Industrial Park of Kifisia HELLAS www alphadynamic eu RUBY025FDA...

Страница 2: ...12 3 4 Pump in submerged operation 12 3 5 Connecting to the product circuit 12 3 6 Noise emissions 2003 10 EC 13 3 7 Temperature range of the diaphragm material 13 3 8 Temperature range of the Housing...

Страница 3: ...3...

Страница 4: ...4...

Страница 5: ...ntenance or repair of the pump must have read and understood these instructions especially the chapter on Health and Safety This applies in particular for those who are only occasionally involved in w...

Страница 6: ...pment for use in potentially explosive atmospheres Basic method and requirements EN ISO 80079 37 Non electrical equipment for explosive atmospheres No electrical type of protection by constructional s...

Страница 7: ...l consumable material such as diaphragms ball seats balls and others The warranty does not cover parts damaged as a consequence of incorrect installation carelessness neglect incorrect maintenance or...

Страница 8: ...d maintenance manual have been analysed whilst the analysis of the risks associated with the interface with other system components must be carried out by the installer The user is responsible for cla...

Страница 9: ...not be used with fluids that arc not compatible with its construction materials or in a place containing incompatible fluids WARNING installing the pumps without on off valves on the intake and deliv...

Страница 10: ...eter and length Position the pump as close as possible to the point of collection within 2 5 m and in any case never more than 5 m The diameter of the intake pipe must never be smaller than the connec...

Страница 11: ...ef valves pressure gauges flow control valves and shut off valves 6 Thoroughly examine the alignment of the pump with the pipelines in order to avoid strain and premature wear 7 Check all pipelines fo...

Страница 12: ...n operation RubyAir Operated Diaphragm Pumps are dry self priming Depending on the pump design a suction head of max 9 m Wc can be reached when the suction line is filled 3 4 Pump in submerged operati...

Страница 13: ...ucted nor limited to avoid either cavitation or pneumatic motor strain Connection off the product circuit finishes here 3 6 Noise emissions 2003 10 EC In a room with several pumps you may experience a...

Страница 14: ...housings by untying the screws gradually and cyclically Step 4 Detach the diaphragm from the central block by hand and untie it with a left rotation Step 5 Untie the opposite housing and pull the dia...

Страница 15: ...p 3 We put the sealing o ring of the lateral cap Step 4 We install the pilot shaft Step 5 Then we install the cap up to the safety point Step 6 Then we install the safety we reverse the central block...

Страница 16: ...4 Assembling Diaphragm installation Step 5 We put at the pump air entrance air of 0 5 bar pressure and we see in which side of the block the entrance holes at the back of the di aphragm are releasing...

Страница 17: ...intenance engineers In event of abnormal behaviour and in order to fix faults please refer to the following troubleshooting instructions WARNING For more serious problems we strongly recocomend that y...

Страница 18: ...18 6 0 Technical data 6 1 Dimensional drawings...

Страница 19: ...te 165 L min Air inlet 1 2 Suction Discharge port DN 40 TRICLAMP Suction lift dry 4 m Max Solid size diameter 3 5 mm The curves and performance values refer to pumps with submerged suction and a free...

Страница 20: ...r inlet 1 2 Suction Discharge port DN 40 TRICLAMP Suction lift dry 4 m Max Solid size diameter 3 5 mm The curves and performance values refer to pumps with submerged suction and a free delivery outlet...

Страница 21: ...inlet 1 2 Suction Discharge port DN 40 TRICLAMP Suction lift dry 4 m Max Solid size diameter 3 5 mm The curves and performance values refer to pumps with submerged suction and a free delivery outlet...

Страница 22: ...LL SEATS 4 2 SUCTION MANIFOLD 1 19 RETAINING RING AIR VALVE 2 3 DISCHARGE MANIFOLD 1 20 AIR CONTROL VALVE 1 4 PUMP HOUSING 2 21 HOUSING PUMP SCREW 16 5 DIAPHRAGMS 2 22 BALT 16 6 PISTON INNER 2 22A NUT...

Страница 23: ...R025 0140 SILANCER 025 1 25 12A R025 0140A SUPPORT SILENCER 025 1 25 13 R025 0185 AIR EXHAUST SCREW 2 25 14 R025 0141 AIR EXHAUST COVER 1 25 15 R025 0171 VALVE SEAT ORING DOWN 025 PTFE 4 25 16 R025 01...

Страница 24: ...ALPHADYNAMIC PUMPS AirOperatedDiaphragmPumps Industrial Park of Kifisia HELLAS www alphadynamic eu VER 01 2021 VER 02 2021...

Отзывы: