 Max transmission distance can reach 1.000m (RVS 2×1mm

2

 Max physical bandwidth can reach 200Mbps 

 Support power over cable technology 

 Transparent transmission, no adjustment and no need to change the upper software 

 Low power consumption, communication channel dynamic adjustment and   

      high performance error correction coding technology 

 
 
 
 

 

 

 

 

 

 
 
T

elephone Line: Category 3 or above      Power Line: RVV, RVS, RVVP, RVB 2×0.5mm2    UTP Cable: Category 5 or above

 

 
 

 

 

 

 

 

 

 

 

 

     

RJ45 port by EIA / TIA568B                        Power Adapter by 12VDC/1A, 5mm female power port (

Optional

 

 

Содержание VC-350

Страница 1: ...r line and so on The max transmission distance can reach 1 000 meters and the max physical bandwidth can reach 200Mbps This device contains the Master and Slave unit which supports point to point and point to multipoint network transmission Now it has a 2P terminals for your choices to connect 2 wire cables It can greatly simplify the project cabling apply to expand network system and transmit sig...

Страница 2: ...ission no adjustment and no need to change the upper software Low power consumption communication channel dynamic adjustment and high performance error correction coding technology Telephone Line Category 3 or above Power Line RVV RVS RVVP RVB 2 0 5mm2 UTP Cable Category 5 or above RJ45 port by EIA TIA568B Power Adapter by 12VDC 1A 5mm female power port Optional ...

Страница 3: ...liance IEEE1901 IEEE802 3 Up down Agreement CSMA CA Physical Speed 200Mbps Encryption Way 128 bit AES Encryption Physical Characteristic Dimension L W H 98mm 86 5mm 25mm Material Aluminum Net Weight 150g PC Operating Environment Working Temperature 20 60 Storage Temperature 55 125 Working Humidity 20 85 Non condensation Storage Humidity 10 90 Non condensation ...

Страница 4: ...al of B line of 2 wire 10 Connect the UTP cable of network equipment to RJ45 port of slave unit 4 Connect power supply 12VDC to the power port 11 Connect power supply 12VDC to the power port 5 Power indicator is always on 12 Power indicator is always on 6 Network data indicator quickly blinks when data transmission is normal 13 Network data indicator it quickly blinks when data transmission is nor...

Страница 5: ...nt with new IP devices while reusing the installed wire In generally there are two connections types One is typical connection Figure 1 above and the other is Bus architecture and Daisy Chain Connection Figure 2 and 3 Below You can choose the connection type in line with actual environment Figure 2 Bus architecture Installation ...

Страница 6: ...ation VC 350 can support Power and Ethernet simultaneous transmission When Ethernet signal transmission in power line to avoid power line interference you should install Power Filter VC 3 POWFI on each VC 350 unit installation diagram as below ...

Страница 7: ...nce 3 Long distance cable connection must be formal connection methods such as welding or using connectors 4 Coaxial cable twisted pair cable telephone line and power line all can be used to transmit network data signal in projects A variety of cables arbitrary mixed connection also can reduce the quality of signal 5 Please choose matching power supply 12VDC 1A 6 If need to transmit power at the s...