Publication date: Jan., 2009
37
Revision A1
Daylight Saving:
Daylight saving is adopted in some countries. If set, it will adjust the time
lag or in advance in unit of hours, according to the starting date and the
ending date. For example, if you set the day light saving to be 1 hour.
When the time passes over the starting time, the system time will be
increased one hour after one minute at the time since it passed over. And
when the time passes over the ending time, the system time will be
decreased one hour after one minute at the time since it passed over.
The switch supports valid configurable day light saving time is –5 ~ +5
step one hour. The zero for this parameter means it need not have to
adjust current time, equivalent to in-act daylight saving. You don’t have to
set the starting/ending date as well. If you set daylight saving to be non-
zero, you have to set the starting/ending date as well; otherwise, the
daylight saving function will not be activated.
Default for Daylight Saving: 0.
The following parameters are configurable for the function Daylight
Saving and described in detail.
Day Light Saving Start :
This is used to set when to start performing the day light saving time.
Mth:
Range is 1 ~ 12.
Default: 1
Day:
Range is 1 ~ 31.
Default:
1
Hour:
Range is 0 ~ 23.
Default:
0
Day Light Saving End :
This is used to set when to stop performing the daylight saving time.
Mth:
Range is 1 ~ 12.
Default: 1
Day:
Range is 1 ~ 31.
Default: 1
Hour:
Range is 0 ~ 23.
Default: 0
Содержание ES-2410C
Страница 1: ......
Страница 7: ...Publication date Jan 2009 vii Revision A1 Revision History Release Date Revision 1 15 01 19 2009 A1...
Страница 46: ...Publication date Jan 2009 Revision A1 38 Fig 3 5...
Страница 158: ...Publication date Jan 2009 Revision A1 150 Fig 3 85 Fig 3 86 Fig 3 87...
Страница 171: ...Publication date Jan 2009 163 Revision A1 Fig 4 1...
Страница 282: ...Publication date Jan 2009 Revision A1 274 22 1 0 Disable 23 1 0 Disable 24 1 0 Disable 25 1 0 Disable 26 1 0 Disable...
Страница 289: ...Publication date Jan 2009 281 Revision A1 Note Any specification is subject to change without notice...
Страница 291: ...Publication date Jan 2009 283 Revision A1...