![RTscan RT230H Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/rtscan/rt230h/rt230h_user-manual_1498179029.webp)
Enter Setup
RT
23
0H
Us
er
Gu
id
e
RT
23
0H
Us
er
Gu
id
e
29
*
* Exit Setup
Sense Mode
If the Sense Mode is enabled, the RT230H activates a decode session every time it detects a change in
ambient illumination. The decode session continues until the barcode is decoded or the decode session
timeout expires.
Driving the TRIG pin on the host interface connector low can also activate a decode session. The decode
session continues until the active trigger signal is no longer present or the barcode is decoded or the decode
session timeout expires. The trigger signal needs to be negated before the RT230H is able to monitor
ambient illumination again.
Sense Mode
Decode Session Timeout
This parameter sets the maximum time decode session continues during a scan attempt. If the timeout
expires or the barcode is decoded, the RT230H goes back to monitoring ambient illumination. It is
programmable in 1ms increments from 0ms to 3,600,000ms. The default setting is 3,000ms. To learn how to
program this parameter, see
Appendix 5
.
Decode Session Timeout
Image Stabilization Timeout
The image stabilization timeout is programmable in 1ms increments from 0ms to 1,600ms. The default
setting is 500ms.To learn how to program this parameter, see
Appendix 5
.