5
Specifications
NOTE:
The TBX–Tribus supports up to eight (8) frames in non-redundant mode. Slot 10 should be used if a third TBX–
Tribus card is needed.
Board Performance
Throughput Per Link:
360Mb/sec
SFP Fiber Transceivers:
Voltage:
3.3 V Rails
Standard Rate:
SONET OC12 or Gigabit Ethernet
Recommended Parts:
Multi-Mode:
Finisar - FTLF8519P2BNL (Oxide VCSEL, Maximum reach of 550m)
Single Mode:
Finisar - FTLF1422P1BTL (1310nm, Maximum reach 40km)
Fiber Cable Connector Type:
Multiple Mode Fiber LC–LC Duplex Connector – max length 500m (546.8 yd.)
Single Mode Fiber LC–LC Duplex Connector – max length 40km (24.9 miles)
Configuration Requirements
An MCII-e Master Controller card must be installed in the same frame as the TBX-Tribus. For more information, see
the MCII-e User Manual which can be found at www.rtsintercoms.com.
TABLE 1.
Systems Supported by the TBX-Tribus Card
Links Used
# TBX Cards
per Frame
System
Frames Supported
Channels
1
1
AIO-8
2
256
1
1
AIO-16
2
512
3
1
AIO-8
3
384
3
1
AIO-16
3
768
6
1
AIO-8
4
512
6
1
AIO-16
4
880
10
2
AIO-8
5
640
10
2
AIO-16
5
880
15
2
AIO-8
6
768
15
2
AIO-16
6
880
21
2
AIO-8
7
880
21
2
AIO-16
7
880
28
3
AIO-8
8
880
28
3
AIO-16
8
880
Содержание TBX - TriBus ADAM
Страница 1: ...ADAM TBX TriBus Triple Bus Expander for ADAM 93507838000 Rev A 12 2008...
Страница 4: ......
Страница 6: ......
Страница 14: ...10...
Страница 15: ...11 Figure 2 Eight Frame Tribus System Non Redundant...
Страница 16: ...12...
Страница 20: ...16...
Страница 29: ...25 FIGURE 38 Base 8 Port Numbering scheme with both AIO 16 and an AIO 8 card installed...
Страница 48: ......