18
Configuration
To
configure the TBX-Tribus card
, the following steps must be completed for the Intercom System to be active:
Step 1
Configure each MCII-e Master Controller IP Address for the Ethernet (page 18)
Step 2
Configure the size of your Intercom system for each frame (page 19)
NOTE:
Each frame must be configured exactly the same. The number of ports must not exceed the number
of ports allowed for the number of frames in the intercom system.
Step 3
Configure the frame using the Frame Mapping window in AZedit (page 23)
Configure each MCII-e Master Controller IP Address for the Ethernet
To
configure the IP Address for the MCII-e
, do the following:
1.
Verify you are
serially connected to AZedit
.
You must be connected serially to make any changes to the Ethernet Setup window in AZedit
.
2.
Open
AZedit
.
3.
From the Options menu, select
Ethernet Setup
.
The Ethernet Setup window appears
.
4.
In the IP Address field, enter the
IP Address
for the MCII-e.
5.
In the Network Mask field, enter the
Network Mask
for the MCII-e, if applicable
6.
In the Default Gateway field, enter the
Default Gateway
for the MCII-e, if applicable.
NOTE:
If you are unsure of your IP Address, Network Mask, or Gateway Address, contact your System
Administrator for this information.
7.
Click
Apply
.
The IP Address is set for the MCII-e
.
8.
Repeat
steps 1-8
for each frame in your system.
Содержание TBX - TriBus ADAM
Страница 1: ...ADAM TBX TriBus Triple Bus Expander for ADAM 93507838000 Rev A 12 2008...
Страница 4: ......
Страница 6: ......
Страница 14: ...10...
Страница 15: ...11 Figure 2 Eight Frame Tribus System Non Redundant...
Страница 16: ...12...
Страница 20: ...16...
Страница 29: ...25 FIGURE 38 Base 8 Port Numbering scheme with both AIO 16 and an AIO 8 card installed...
Страница 48: ......