RTS SSA-424 Скачать руководство пользователя страница 7

SSA-424 U

SER

 M

ANUAL

 7

2

Installation

2.1

U

NPACKING

 

AND

 

INSPECTING

Immediately upon receipt of the equipment, carefully
inspect the shipping container and the contents for
any discrepancies or damage.  Should there be any,
notify the freight company and the dealer at once.
The following items are included:

Qty

Description

1

SSA-424 Dual Digital Hybrid

1

Power Pack with cord,100-250 VAC, 50/60Hz

1

Warranty Card

1

User Instruction Manual

2.2

M

OUNTING

Place the SSA-424 on a desktop, or install it in an
equipment rack using an RTS MCP Rack Mount Kit.
Several rack mount options are available (Figure2,
page 8).  There are no special ventilation require-
ments for the SSA-424, but allow for ventilation
around the power pack.

If the SSA-424 has the call signal option, the
power indicator flashes whenever a call
signal is received from either 2-wire line, and
activity on the level display helps to indicate
which line is calling.  If the SSA-424 is
positioned near the 4-wire operator, this can
be used as an incoming call indication for the
4-wire system, if desired (although other
methods are available as described in
paragraph 2.5).

You may wish to read about the internal
mode DIP switches before mounting the
SSA-424.  For further information, see Mode
Switch Settings, page 16.

2.3

4-W

IRE

 A

UDIO

 C

ONNECTIONS

2.3.1

ADAM, ADAM CS, 

OR

 Z

EUS

 A

UDIO

C

ONNECTION

1 Use standard 9-pin or RJ11 keypanel cables.

Connect from one port of your intercom system
to J2A or J3A (System A connection) on the
back of the SSA-424.  Connect from another
port to J2B or J3B (System B connection).

2 On the SSA-424 front panel, set the 4W

LEVEL REF SEL switches to the +8dB posi-
tion.

2.3.2

A

UDIO

 C

ONNECTIONS

 

FOR

 O

THER

 4-

WIRE

C

OMMUNICATIONS

 S

YSTEMS

1 Construct 9-pin or RJ11 cables to connect from

you 4-wire system to the SSA-424.  To connect to
the System A hybrid, use either J2A or J3A; for
the System B hybrid, use either J2Bor J3B.  Pin
connections are as follows:

9-Pin Connection
Connector Type (on SSA-424 end of cable): 9-pin
male D-subminiture

Pin 1:

No connection

Pin 2:

No connection

Pin 3:

No connection

Pin 4:

Balanced Audio + output (to 4-wire
system)

Pin 5:

Balanced Audio - output (to 4-wire
system)

Pin 6:

No connection

Pin 7:

Balanced Audio - input (from 4-wire

system)
Pin 8:

Balanced Audio + input (from 4-wire

system)
Pin 9:

No connection

RJ11 Connection
Connector Type (on SSA-424 end of cable):
RJ11 plug

Pin 1:

No connection

Pin 2:

Balanced Audio + input (from 4-wire
system)

Pin 3:

Balanced Audio + output (to 4-wire
system)

Pin 4:

Balanced Audio -  output (to 4-wire
system)

Pin 5:

Balanced Audio -  input (from 4-wire
system)

Pin 6:

No connection

2 On the SSA-424 front panel, set the 4W LEVEL

REF SEL switches to the position which most
closely matches the audio input and output levels
of your 4-wire system.  If you don’t know the
levels, 4dB for now.

Содержание SSA-424

Страница 1: ...ER 4W LEVEL REF SEL LEVEL SET SYSTEM A 4W 2W TO TO 2 BAL 1 1 2 BAL TW CHAN SEL 10dB 0dB 4dB 8dB 12dB 15 12 9 6 0 3 6 9 12 3 4W LEVEL REF SEL LEVEL SET SYSTEM B 4W 2W TO TO 2 BAL 1 1 2 BAL TW CHAN SEL...

Страница 2: ...ns If a repair is necessary contact the dealer where this unit was purchased If repair through the dealer is not possible obtain a Return Authorization from Customer Service Department RTS Telex Commu...

Страница 3: ...OM AUDIO CONNECTION 10 2 4 4 OTHER 2 WIRE AUDIO CONNECTION 10 2 5 4 WIRE CALL SIGNAL CONNECTIONS 11 2 5 1 CALL SIGNAL CONNECTIONS FOR ADAM ADAM CS AND ZEUS 11 2 5 2 CALL SIGNAL CONNECTIONS FOR OTHER 4...

Страница 4: ...4 SSA 424 USER MANUAL...

Страница 5: ...red Direct ADAM Zeus Audio Connection Accepts standard ADAM Zeus DB9 or RJ11 keypanel cables Transformer Isolated All audio inputs and outpus are transformer isolated to prevent ground loops and hum C...

Страница 6: ...is located at the right end of the back panel This is a locking DIN connector The remainder of the back panel is divided into connectors for the two separate hybrids Connectors are labeled with J numb...

Страница 7: ...IONS 2 3 1 ADAM ADAM CS OR ZEUS AUDIO CONNECTION 1 Use standard 9 pin or RJ11 keypanel cables Connect from one port of your intercom system to J2A or J3A System A connection on the back of the SSA 424...

Страница 8: ...tions Side By Side Rack Mount Configuration Using an MCP1 Rack Mount Kit Single unit Rack Mount Configuration Using an MCP2 Rack Mount Kit Tandem Configuration Using an MCP4 Tandem Mount Kit Console M...

Страница 9: ...Audiocom 1 channel cables Connect one Audiocom channel to the J1A connector on the back of the SSA 424 System A Connect a second Audiocom channelto the J1B connector System B If your Audiocom system...

Страница 10: ...m A hybrid Use the J1B connector to connect a second 2 wire line to the System B hybrid The pin configuration for the J1A and J1B connectors depends on whether you are connecting a balanced or unbalan...

Страница 11: ...ion of the GPI outputs By default these outputs are set to duplicate the actio of the RTS FR9528 Relay Frame accessory This is the correct setting for use with the SSA 424 To check the AZedit setting...

Страница 12: ...t s r e b m u N t u p t u O I P G s r e b m u N t u p t u O I P G s r e b m u N t u p t u O I P G s r e b m u N t u p t u O I P G s r e b m u N t u p t u O I P G s r e b m u N n i P t c a t n o C y a...

Страница 13: ...em if desired and the level display should provide an indication of which line is calling COMMON 4 WIRE CALL SEND CALL ENABLE INHIBIT 1 5 4 3 2 6 7 8 9 DB9F View from solder or crimp side CONNECTOR PI...

Страница 14: ...o generate and receive a 20kHz signal superimposed on the audio as follows Balanced Audio Configuration Pin1 No connection Pin 2 Balanced 20 kHz Input Output Pin 3 Balanced 20 kHz Input Output SSA 424...

Страница 15: ...nment for any key that is assigned to talk to the SSA 424 However this will cause the call lights to flash on the 2 wire line during the entire conversation Another solution is to assign a dedicated k...

Страница 16: ...s n i g e b n o i t a s r e v n o c r e t f a s d n o c e s 0 6 l i t n u e d o m x e l p u d l l u f n i s y a t S e n i l e r i w s i h T s e s a e c n o i t a s r e v n o c r e t f a s d n o c e s...

Страница 17: ...completes the adjustment 4 4 CALL SIGNAL OPTION CARD INSTALLATION Use these instructions to install a Call Signal Option Card in an SSA 424 that was originally ordered without it 1 Disassemble the SSA...

Страница 18: ......

Отзывы: