RTS SSA-424 Скачать руководство пользователя страница 5

SSA-424 U

SER

 M

ANUAL

 5

1

Description and
Specifications

1.1

G

ENERAL

 D

ESCRIPTION

The SSA-424 Dual Digital Hybrid intervaces two, 2-
wire intercom lines to two, 4-wire intercom lines.
Unlike earlier analog hybrids, the SSA-424 features
advanced digital signal processing to achieve
automatic nulling of the 2-wire lines.  Plus, each
hybrid features convenient peak-reading level
meters to quickly match the levels between the lines
that are being interfaced.  The result is easy and
accurate setup.  With the SSA-424, all need for test
tones, nulling adjustments and ducking adjustments
have been eliminated.

Compatible 2-wire intercom systems include RTS™
TW, Audiocom

®

, and Clear-Com

®

.  Compatible 4-

wire intercom systems include Telex’s ADAM™,
ADAM™CS, and Zeus™ Digital Matrix Intercom
Systems.

The SSA-424 is also available with optional call
signal interfacing.  This option provides bidirectional
call signal compatibility between the 2-wire and 4-
wire intercom systems.

With features like digital signal processing, peak-
reading level meters and optional call signal interfac-
ing, the SSA-424 Dual Digital Hybrid assures ease
of setup and maximum transparency between
intercom systems.

1.2 G

ENERAL

 F

EATURES

Two Independent Hybrids: Interface two separate
2-wire lines to two separate 4-wire lines.

Automatic Nulling:  Digital hybrids eliminate all
nulling and ducking adjustments.  Quick, trouble-free
setup.  Puts an end to concerns about echo and
feedback when interfacing 2-wire lines.

Peak Reading Level Meters:  Quick and accurate
visual audio level adjustment.  No extra setup equip-
ment or guesswork is required.

Direct ADAM/Zeus Audio Connection:  Accepts
standard ADAM/Zeus DB9 or RJ11 keypanel cables.

Transformer Isolated:  All audio inputs and outpus
are transformer isolated to prevent ground loops and
hum.

Call Signal Option:  Detects call signals from any of
the compatible 2-wire intercom systems, and then
provides a +5VDC output to the 4-wire intercom
system.  Accepts a contact closure input from the 4-
wire system and converts it to the call signal format
required by the 2-wire system.  The SSA-424 can be
directly connected to an ADAM, ADAM CS, or Zeus
GPI (General Purpose Interface).  GPI inputs can be
programmed to activate call signals and audio paths
to any of the available types of communication within
the 4-wire system, including intercom ports, camera
ISO circuits, IFB circuits, etc.  GPI outputs can be set
up to place calls only from a specific keypanel within
the 4-wire system, or from any keypanel within the 4-
wire system that wishes to call the 2-wire system.

Half-rack Wide, 1RU High:  Two SSA-424’s fit into a
single rack space.  Compatible with RTS TW rack
mount hardware.  Can be mixed with other TW
equipment.

Universal Power Pack:  Ready for worldwide use.
Automatically accepts any mains voltage from 100-
250 VAC, 50/60 Hz.  Power pack equipped with
locking DIN connector for attachment to the SSA-
424.

AUX

J4B

J3B

J2B

J1B

J1A

J2A

J3A

J4A

AUX

4 WIRE SYSTEM

4 WIRE SYSTEM

2 WIRE SYSTEM

Telex Communications, Inc., Made in U.S.A.

-15 -12

-9

-6

0

+3

+6

+9 +12

LEVEL

SET

SYSTEM B

-15 -12

-9

-6

-3

0

+3

+6

+9 +12

4W

2W

TO

TO

SSA-424

4W LEVEL

REF SEL

1

2

BAL

2W CHAN SEL

LEVEL

SET

SYSTEM A

-3

4W

2W

TO

TO

POWER

4W LEVEL

REF SEL

1

2

BAL

2W CHAN SEL

1

2

BAL

OFF

OFF

TM

RTN

+5V

RTN

+15V

-15V

-15V  0.3A

+15V  1.6A

+5V  3A

J5 POWER

0dB

+4dB

+8dB

+12dB

-10dB

0dB

+4dB

+8dB

+12dB

-10dB

1

2

BAL

OFF

OFF

Figure 1.  SSA-424 Reference View

Содержание SSA-424

Страница 1: ...ER 4W LEVEL REF SEL LEVEL SET SYSTEM A 4W 2W TO TO 2 BAL 1 1 2 BAL TW CHAN SEL 10dB 0dB 4dB 8dB 12dB 15 12 9 6 0 3 6 9 12 3 4W LEVEL REF SEL LEVEL SET SYSTEM B 4W 2W TO TO 2 BAL 1 1 2 BAL TW CHAN SEL...

Страница 2: ...ns If a repair is necessary contact the dealer where this unit was purchased If repair through the dealer is not possible obtain a Return Authorization from Customer Service Department RTS Telex Commu...

Страница 3: ...OM AUDIO CONNECTION 10 2 4 4 OTHER 2 WIRE AUDIO CONNECTION 10 2 5 4 WIRE CALL SIGNAL CONNECTIONS 11 2 5 1 CALL SIGNAL CONNECTIONS FOR ADAM ADAM CS AND ZEUS 11 2 5 2 CALL SIGNAL CONNECTIONS FOR OTHER 4...

Страница 4: ...4 SSA 424 USER MANUAL...

Страница 5: ...red Direct ADAM Zeus Audio Connection Accepts standard ADAM Zeus DB9 or RJ11 keypanel cables Transformer Isolated All audio inputs and outpus are transformer isolated to prevent ground loops and hum C...

Страница 6: ...is located at the right end of the back panel This is a locking DIN connector The remainder of the back panel is divided into connectors for the two separate hybrids Connectors are labeled with J numb...

Страница 7: ...IONS 2 3 1 ADAM ADAM CS OR ZEUS AUDIO CONNECTION 1 Use standard 9 pin or RJ11 keypanel cables Connect from one port of your intercom system to J2A or J3A System A connection on the back of the SSA 424...

Страница 8: ...tions Side By Side Rack Mount Configuration Using an MCP1 Rack Mount Kit Single unit Rack Mount Configuration Using an MCP2 Rack Mount Kit Tandem Configuration Using an MCP4 Tandem Mount Kit Console M...

Страница 9: ...Audiocom 1 channel cables Connect one Audiocom channel to the J1A connector on the back of the SSA 424 System A Connect a second Audiocom channelto the J1B connector System B If your Audiocom system...

Страница 10: ...m A hybrid Use the J1B connector to connect a second 2 wire line to the System B hybrid The pin configuration for the J1A and J1B connectors depends on whether you are connecting a balanced or unbalan...

Страница 11: ...ion of the GPI outputs By default these outputs are set to duplicate the actio of the RTS FR9528 Relay Frame accessory This is the correct setting for use with the SSA 424 To check the AZedit setting...

Страница 12: ...t s r e b m u N t u p t u O I P G s r e b m u N t u p t u O I P G s r e b m u N t u p t u O I P G s r e b m u N t u p t u O I P G s r e b m u N t u p t u O I P G s r e b m u N n i P t c a t n o C y a...

Страница 13: ...em if desired and the level display should provide an indication of which line is calling COMMON 4 WIRE CALL SEND CALL ENABLE INHIBIT 1 5 4 3 2 6 7 8 9 DB9F View from solder or crimp side CONNECTOR PI...

Страница 14: ...o generate and receive a 20kHz signal superimposed on the audio as follows Balanced Audio Configuration Pin1 No connection Pin 2 Balanced 20 kHz Input Output Pin 3 Balanced 20 kHz Input Output SSA 424...

Страница 15: ...nment for any key that is assigned to talk to the SSA 424 However this will cause the call lights to flash on the 2 wire line during the entire conversation Another solution is to assign a dedicated k...

Страница 16: ...s n i g e b n o i t a s r e v n o c r e t f a s d n o c e s 0 6 l i t n u e d o m x e l p u d l l u f n i s y a t S e n i l e r i w s i h T s e s a e c n o i t a s r e v n o c r e t f a s d n o c e s...

Страница 17: ...completes the adjustment 4 4 CALL SIGNAL OPTION CARD INSTALLATION Use these instructions to install a Call Signal Option Card in an SSA 424 that was originally ordered without it 1 Disassemble the SSA...

Страница 18: ......

Отзывы: