RVON-16
Installation 11
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.291
Rev. 06
Switches and Connections
IMPORTANT
:
You must remove the card from the frame in order to change any DIP switch settings.
The RVON-16 card, unlike the RVON-8 card has two banks of eight DIP Switches.
DIP Switch 1
AZedit Configuration Disable
Closed: Configuration via AZedit is disabled.
Open (Default): Configuration via AZedit is enabled.
Description: Disables configuration changes via AZedit. AZedit is still able to view the RVON
configuration and status. The configuration can be changed via the serial and Telnet connections.
DIP Switch 2
Configuration File Save Location
Closed: The RVON card holds the definitive configuration file.
Open
(Default)
:
The Master Controller holds the definitive configuration file.
Description: Assigns where the configuration file for the RVON products is to be stored, either on the
Master Controller or on the RVON card.
DIP Switch 3
Not Used.
Keep in
Open
position.
DIP Switch 4
Inhibit Reset
Closed: When enabled, the card is prevented from resetting after 30 seconds of no communication
with the system controller.
Open (Default): When disabled, the card resets after 30 seconds of no communication with the
system controller.
Description: Allows pass-through serial data to continue when the intercom is otherwise down (i.e.,
upgrades). Mainly used to keep trunking connections open when disruptions in communication on
the card occur.
DIP Switch 5
Password Reset
Closed: Resets the Telnet user name and password to their default values. The password is case
sensitive:
User: telex
Password: password
Also, this setting disables RVONedit and resets the authentication table in RVONedit.
Open (Default): Uses current username and password.
Description: Enables the user to reset the Telnet username and password.
DIP Switch 6
Serial Monitor Enable
Closed: Enables a serial monitor on back card DB9 via Serial Port 1.
Open
(Default): Enables pass-through serial port via the back card DB9 on both serial port 1 and
serial port 2.
NOTE:
Serial Port 2 is always seen as the pass-through port.
Description: Selects DB9 serial configuration.
Содержание RVON-16
Страница 1: ...F 01U 193 291 Rev 06 DECEMBER 2011 RVON 16 RTS Voice Over Network...
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 193 291 Rev 06 iv RVON 16...
Страница 10: ...6 Introduction RVON 16 Bosch Security Systems Inc Technical Manual F 01U 193 291 Rev 06...
Страница 42: ...38 RVON 16 Bosch Security Systems Inc Technical Manual F 01U 193 291 Rev 06...
Страница 45: ...RVON 16 41 Bosch Security Systems Inc Technical Manual F 01U 193 291 Rev 06 FIGURE 11 ADAM Trunking Via RVON 8...
Страница 48: ...Bosch Security Systems Inc Technical Manual F 01U 193 291 Rev 06 44 RVON 16 FIGURE 14 RVON 16 Trunking...
Страница 49: ...RVON 16 45 Bosch Security Systems Inc Technical Manual F 01U 193 291 Rev 06 Notes...
Страница 50: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...