Section 6 — Exploded Views and Parts List

RTS “W” Type Transfer Switch

400 A Switch Assembly – Drawing No. 0G1510$

ITEM PART 

NO.  QTY.  DESCRIPTION

 1 

0D72

9

4 1 

XFER 

S

W-W 400A600V2P 

 2 

0A7

8

22 6 

LUG, 

S

LDL

SS

 600/250-1/0X1/4-2

8

 

3

 026

9

02 5 

S

CREW TAPTITE #

8

-

3

2X1/4 BP

 4 

0C7

9

07J 

COVER LUG 2P 400AMP

 5 

024526 

S

CREW HHTT 5/16-1

8

 X 

3

/4 CZ

 6 

057

3

2

9

 1 

LUG, 

S

OLDERLE

SS

 

3

50-#6X1

3

/

3

2 AL/CU

 7 

0274

8

2 1 

WA

S

HER 

S

HAKEPROOF EXT 5/16 

S

TEEL

 

8

 0220

9

9

 WA

S

HER LOCK M6-1/4

 

9

 0C

8

275 4 

S

CREW PPHM D

S

EM

S

 M4-.7 X 10 ZNC

 (2)  10 

0D2

8

06 1 

FU

S

EBLOCK 

3

0A 600V 2PO

S

 W/

S

Q

 11 

0

9

0

388

 

3

 

S

CREW TAPTITE M6-1.0 X 12 MM

 12 

0A14

9

5 6 

S

CREW TAPTITE M4-.7 X 10 MM

 (2)  1

3

 06

3

617 

RELAY PNL 12VDC DPDT 10A@240VA

 14 

047411 

S

CREW HHC M6-1.0 X 16 G

8

.

8

 

 15 

0A1661 

RIVET, 

POP

 16 

0F40

3

4 1 

A

SS

Y. NEUTRAL BLOCK 

3

00/400A

 17 

0F5

93

5 1 

RT

S

 

3

R ENCLO

S

URE 24X

3

6X10 

  1

8

 0F5

939

 1 

COVER 

TRAN

S

FER 

S

WITCH

  1

9

 0C

83

0

8

 2 

DECAL 

TERMINAL 

S

HOCK HAZARD

 20 

0C2262 

DECAL 

TERMINAL 

S

TRIP

 21 

0F6165 

WA

S

HER, NYLON

 22 

0G1520 

DECAL,DATA 

XFER 

S

W 400A,240V

  2

3

 

064101 

NUT HEX FL WHIZ 

3

/

8

-16 

 24 

0F5

9

40 1 

S

UBPLATE,100A T

S

 

3

R 4

8

0V

 25 

0

8

76

8

0 1 

NUT 

WING 

M6-1.0

 26 

06

33

7

8

 4 

HOLDER 

CABLE 

TIE

  27 

064761 

TIE WRAP UL 5.6" X .10" NATL

  2

8

 06

33

21 1 

HANDLE 

TRAN

S

FER 

S

WITCH 1-400A

  2

9

 07

3

5

9

0A 2 

FU

S

E 5A X B

SS

 HLDR7

3

5

9

1

 

3

0 0D

3

5

8

7 1 

DECAL,FU

S

E REPLACEMENT

 

3

067210A 

DECAL GROUND LUG

 

3

2 0A

9

457 1 

DECAL 

NEUTRAL

 

33

 

0D4545 

DECAL MANUAL OPERATION

 (1) 

3

4 0F612

9

 1 

DECAL, 

TE

S

S

EQUENCE

 

3

5 0

8

1221 

DECAL, UL NAMEPLATE

 

3

6 0A

8

261 6 

S

CREW, HHC

S

 1/4-2

8

 X 5/

8

"

 

3

7 02247

3

 6 

WA

S

HER, FLAT 1/4-6M ZINC

 (2) 

38

 04

88

50 

BLOCK TERM 20A 5 X 6 X 1100V 

 

39

 0F627

3

A 1 

HARNE

SS

 400A 2 POLE RT

S

 (NOT 

S

HOWN)

 40 

02212

9

 1 

WA

S

HER LOCK M

8

-5/16

 41 

0

9

1472 2' 

DUCT 

WIRING 

1X1.5 

 42 

0

9

1472A 

2' 

COVER WIRE DUCT 1 IN

  4

3

 067

989

 

NUT HEX FL WHIZ M

8

-1.25 

(1) CENTER DECAL ON IN

S

IDE OF THE COVER (ITEM #1

8

)

(2) ITEM

S

 INCLUDED WITH HARNE

SS

Содержание KGATX0101400

Страница 1: ...TECHNICAL MANUAL This manual should remain with the unit RTS Automatic Transfer Switch 400A 120 240V Single phase Model No KGATX0101400 A new standard of reliability...

Страница 2: ...occurs must be isolated from the NORMAL UTILITY power source by means of an approved transfer switch Failure to properly isolate the NORMAL and STANDBY power sources from each other may result in inju...

Страница 3: ...nt while standing on metal or concrete place insulative mats over a dry wood platform Work on this equipment only while standing on such insulative mats Never work on this equipment while physically o...

Страница 4: ...erator the generator then supplies the loads When UTILITY returns above a preset level the load is transferred back to the UTILITY and the generator shuts down 1 3 TRANSFER SWITCH DATA LABEL A DATA LA...

Страница 5: ...andby generator power supplies before trying to connect power source and load lines to the transfer switch Supply voltages are extremely high and danger ous Contact with such high voltage power sup pl...

Страница 6: ...fer switch to operate customer accessories remote advi sory lights or remote annunciator devices A suitable power source must be connected to the COMMON C terminal See Figure 2 3 Contact operation is...

Страница 7: ...w B OFF LOAD termi nals T1 T2 T3 are connected to utility termi nals N1 N2 N3 Window A OFF Window B ON LOAD termi nals T1 T2 T3 are connected to emergency terminals E1 E2 E3 Do not use excessive force...

Страница 8: ...ible with transfer switch ratings turn OFF the UTILITY supply to the transfer switch 3 3 2 GENERATOR VOLTAGE CHECKS 1 On the generator panel set the AUTO OFF MANUAL switch to MANUAL position The gen e...

Страница 9: ...stem frequency should be greater than 59 Hz Let the generator run under rated load for at least 30 minutes With unit running listen for unusual noises vibration overheating etc that might indicate a p...

Страница 10: ...RTS W Type Transfer Switch Installation Diagram Drawing No 0F6401 609 6mm 24 0 917mm 36 1 TRIPLE EKO SUITABLE FOR 1 1 25 1 50 CONDUIT 3 PLACES 254mm 10 0 794mm 31 3 60 8mm 2 4 61 3mm 2 4 487mm 19 2 MO...

Страница 11: ...9 Section 5 Electrical Data RTS W Type Transfer Switch Interconnection Diagram Drawing No 0G1944...

Страница 12: ...ITION B A WHITE RED LS2 LS3 LS1 T1 T2 2 3 5 6 1 4 C CONTACTOR ACTUATING COIL GTS TRANSFER SWITCH CONTACTOR LS1 LS2 LS3 LIMIT SWITCHES ACTUATOR TR RELAY TRANSFER TS TERMINAL STRIP CUSTOMER CONNECTION N...

Страница 13: ...05 N1A 205 E1 E1 A 7 1 B 9 3 T1 T2 N1A N2A 126 205 N1A N1A N1A N1A F2 F1 23 194 TS UTILITY 2 UTILITY 1 194 23 23 194 23 194 N1 N2 N2A N2A N2A N2A N2A N2A N1A 23 194 Section 5 Electrical Data RTS W Typ...

Страница 14: ...12 Section 6 Exploded Views and Parts List RTS W Type Transfer Switch 400 A Switch Assembly Drawing No 0G1510...

Страница 15: ...X10 18 0F5939 1 COVER TRANSFER SWITCH 19 0C8308 2 DECAL TERMINAL SHOCK HAZARD 20 0C2262 1 DECAL TERMINAL STRIP 21 0F6165 2 WASHER NYLON 22 0G1520 1 DECAL DATA XFER SW 400A 240V 23 064101 6 NUT HEX FL...

Страница 16: ...MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply...

Отзывы: