Universal Beltpack – BP-6000
Operation and Maintenance 29
Set Local Power
Local Power is set by shorting pins on the J3, J4 and J5 jumper located on the PCBA board. The board
must be removed from the beltpack housing to make this adjustment. For more information on Local
power, see “Local Power” on page 15.
To
set local power
, do the following:
1.
Remove the
two side screws
from the beltpack unit (see below).
IMPORTANT:
There are two red o-rings to strengthen the seal and keep moisture out of the beltpack.
Keep these o-rings with the screw. They can sometimes become lodged in one of the
screw holes.
2.
Carefully slide the
top plate assembly from the beltpack enclosure
just far enough to expose
the entire PCBA board. Take care not to disconnect the connectors from the headers.
Содержание BP-6000
Страница 1: ...F 01U 350 550 Rev 03 May 2018 Universal Beltpack Technical Manual BP 6000...
Страница 4: ...4 Universal Beltpack BP 6000...
Страница 8: ...8 Introduction Universal Beltpack BP 6000 Reference View FIGURE 1 Reference View...
Страница 14: ...14 Introduction Universal Beltpack BP 6000 FIGURE 3 Single Power Supply System FIGURE 4 Two Power Supply System...
Страница 16: ...16 Introduction Universal Beltpack BP 6000...
Страница 20: ...20 Initial Setup and Configuration Universal Beltpack BP 6000 Menu System...
Страница 31: ...Universal Beltpack BP 6000 Operation and Maintenance 31 Notes...