iii)
If remote control device is not be used, make sure the switch is on ‘OFF’
position or welding current will not be adjusted on panel.
WARNING
Before connecting operation please make sure all the power is turned off. The right order is to
connect the welding cable and ground cable to the machine first and make sure they are firmly
connected and then put the power plug to the power source.
MAINTENANCE AND CLEANING
1- Remove dust by dry and clean compressed air regularly, if welding machine is operating in
environment where is polluted with smokes and pollution air, the machine needs to be cleaned
after using.
7-
Pressure of compressed air must be inside the reasonable arrangement in order to prevent
from damaging the small components of inter-machine.
8-
Check inter circuit of welding machine regularly and make sure the cable circuit is
connected correctly and connectors are connected tightly.
9-
Avoid water and steam enter into inter-machine.
10-
If welding machine will not be operated long time, it must be put into packing box and store
in dry environment.
11-
If the machine happens to fail despite the care taken in manufacture and testing, repair
should be carried out by an authorized customer services agent for
RTRMAX power tools
.