The sounder is shipped with the following labels:- 
 

 

A label marking with the appropriate Serial No. and 
manufacturing date on the bottom of the enclosure. 

 

 

A Certification Label as shown in Fig 2 showing all 
relevant certification information.

 

 

 

INSTRUMENTS

KNARESBOROUGH

HG5 8PJ,  UK

Ui=28V  Ii=300mA  Pi=1.2W

WARNING: POTENTIAL 

ELECTROSTATIC DISCHARGING 

HAZARD - SEE INSTRUCTIONS

1180

IS SOUNDER TYPE:DA-132

CERTIFICATE No: IECEx BAS 07.0026X

CERTIFICATE No: Baseefa07ATEX0120X

II 1 G    Ex ia IIC T4  -20°C <T

a

< +55°C

Fig 2 

EMC Compliance 

Immunity to EN61000-6-2 : 2005 
Emissions to EN6100-6-4 : 2007 

 
Environment 

Operating temperature :      -20

°

C to +55

°

Storage temperature:          -20

°

C to +80

°

Humidity:         0-95% RH, non condensing 
 

Protection 

IP65 
 

Construction 

High impact, flame retardant polycarbonate 
 

Cable Entry 

The base has three knockouts, two on the side and 
one on the base, to accommodate a 20mm conduit 
or M20

 

cable glands. 

 

 
Connections 

For conductors up to 2.5mm

2

 

 
 
Recommended IS Interfaces 

Nominal Supply 

Barriers/Isolators 

24V 

M, , 
(M for IIB only) 
 
MTL5521 

12V 

Specification 

 
Standards

: ATEX certified to EN 60079-0:2004 and 

EN60079-11:2007 
IECEx certified to IEC60079-0:2004 and  
IEC60079-11:2006 

 

Approved for   

 II 1G Ex ia IIC T4  (Ta –20

o

C to 

+55

°

C) 

    

Location 

Zone 0, 1 or 2. Gas Group, IIC, IIB or IIA,  
Temp Class up to T4 

 
Certificate No’s   

Baseefa07ATEX0120X

 

IECEx BAS 07.0026X

 

 
Safety Parameters 

Vi = 28V

 

Ii  =  300mA 
Pi =  1.2W 
Ci = Li = 0 
Please  refer  to  EC  Type  Examination  certificates  for  full 
details on suitable interface devices 
 

Supply 

12 to 24VDC +/-20%  
Max current, 44mA @24V, max 40mA @ 12V 
 

 

Table 1 

Special Conditions for use 

The certificate number has an ‘X’ suffix, which indicates that the certificate contains one of more special conditions 
for safe use. These are below:   
 
Electrostatic Risk: The equipment shall not be directly installed in any process where its enclosure might be 
electro-statically charged by the rapid flow of a nonconductive media.  Care must be taken when cleaning, and if 
this is necessary it must be done with a damp cloth. 
 