Labelling
The sounder is shipped with the following labels:-
•
A label marking with the appropriate Serial No. and
manufacturing date on the bottom of the enclosure.
•
A Certification Label as shown in Fig 2 showing all
relevant certification information.
INSTRUMENTS
KNARESBOROUGH
HG5 8PJ, UK
Ui=28V Ii=300mA Pi=1.2W
WARNING: POTENTIAL
ELECTROSTATIC DISCHARGING
HAZARD - SEE INSTRUCTIONS
1180
IS SOUNDER TYPE:DA-132
CERTIFICATE No: IECEx BAS 07.0026X
CERTIFICATE No: Baseefa07ATEX0120X
II 1 G Ex ia IIC T4 -20°C <T
a
< +55°C
Fig 2
EMC Compliance
Immunity to EN61000-6-2 : 2005
Emissions to EN6100-6-4 : 2007
Environment
Operating temperature : -20
°
C to +55
°
C
Storage temperature: -20
°
C to +80
°
C
Humidity: 0-95% RH, non condensing
Protection
IP65
Construction
High impact, flame retardant polycarbonate
Cable Entry
The base has three knockouts, two on the side and
one on the base, to accommodate a 20mm conduit
or M20
cable glands.
Connections
For conductors up to 2.5mm
2
Recommended IS Interfaces
Nominal Supply
Barriers/Isolators
24V
M, ,
(M for IIB only)
MTL5521
12V
M
Specification
Standards
: ATEX certified to EN 60079-0:2004 and
EN60079-11:2007
IECEx certified to IEC60079-0:2004 and
IEC60079-11:2006
Approved for
II 1G Ex ia IIC T4 (Ta –20
o
C to
+55
°
C)
Location
Zone 0, 1 or 2. Gas Group, IIC, IIB or IIA,
Temp Class up to T4
Certificate No’s
Baseefa07ATEX0120X
IECEx BAS 07.0026X
Safety Parameters
Vi = 28V
Ii = 300mA
Pi = 1.2W
Ci = Li = 0
Please refer to EC Type Examination certificates for full
details on suitable interface devices
Supply
12 to 24VDC +/-20%
Max current, 44mA @24V, max 40mA @ 12V
Table 1
Special Conditions for use
The certificate number has an ‘X’ suffix, which indicates that the certificate contains one of more special conditions
for safe use. These are below:
Electrostatic Risk: The equipment shall not be directly installed in any process where its enclosure might be
electro-statically charged by the rapid flow of a nonconductive media. Care must be taken when cleaning, and if
this is necessary it must be done with a damp cloth.