In-Wall Controller
RK3-V
6
CHaPteR 3 | InstallatIOn
mOuntInG OPtIOns
The RK3-V has integrated mounting wings for retrofit installation in new
or existing construction. Additionally, the RK-V can be directly attached
to certain walls (wood, etc.) using screws. An optional drywall rough-in
bracket (RTI part #: 40-20294-22) and preconstruction back box
(RTI part #: 0-205-5) is available for conveniently locating the
RK-V in new construction installations.
WIRInG COnneCtIOn OPtIOns
The RK-V can be wired either from the Control Port or the Removable
Terminal Block. A minimum of -conductor wire is required for basic
operation (+6VDC, GND, and IR DATA). CAT5 cable can be used to
power the RK-V up to 000 feet (00m) if a full wire pair is used for both
+6VDC and GND. For longer distances use the following size of unshielded
multi-conductor cable:
Wire size
distance
20 AWG
00’ (400m)
AWG
2000’ (600m)
nOte:
The IR Data connection does not need to be connected if the RK-V
will be using an Ethernet connection for control.