5
It’s Under Control
®
teRmInals
+16VdC
Positive power supply connection. This should be connected to a
9VDC-6VDC.
Gnd
Common ground connection. Use this ground reference for any device
that is connected to any of the other pins on the connector.
IR data
High current (200mA) IR output connection. This can be used to power
up to 0 infrared mini emitters or an IR blaster, delivering IR trigger
codes to a control processor, or extending IR control over a long
distance (000 ft. max).
PWR status
Voltage power sensing input connection. This can be connected to
a trigger output or switched outlet (using a small wall-mount power
supply) on A/V equipment, current sensors, light sensors, etc. The ON
state sense voltage is VDC – 20VDC. The OFF state sense voltage is
0VDC - 2VDC.
Gnd
Common ground connection. Use this ground reference for any device
that is connected to any of the other pins on the connector.
RelaY CtRl
Voltage trigger output. This can be used to control speaker relays,
screens, window coverings, etc. The output can supply up to 00mA
and has a voltage equal to the input supply.
auX status
Voltage power sensing input connection. This can be connected to
a trigger output or switched outlet (using a small wall-mount power
supply) on A/V equipment, current sensors, light sensors, etc. The ON
state sense voltage is VDC – 20VDC. The OFF state sense voltage is
0VDC - 2VDC.
tRIG Out
Voltage trigger output. This can be used to control speaker relays,
screens, window coverings, etc. The output can supply up to 00mA
and has a voltage equal to the input supply.