SELECTOR VALVE
PURGE
FLUSH
CONTROL VALVE
L
OFF
O
Y
L
W
S
ACF 3000
-
PURGE
FLUSH
Purge
1.
Slowly turn the Control Valve toward the
SLOWLY position and observe the
discharge hose. Proceed to the next step
when all of the liquid has been removed
from the hose .
2.
Slowly turn the Control Valve towards
PURGE. Wait one minute before
proceeding with the next step.
3.
Turn the Selector Valve completely to
PURGE.
4.
Purge the component for a minimum of 30 minutes to ensure that it is completely dry.
5.
Turn the Control Valve to OFF.
6.
Disconnect the “IN” and “OUT” hoses from the adapter fittings.
7.
Disconnect the adapter fittings from the component.
8.
The Coalescing Filter will need to be drained periodically. Turn the drain valve at the
bottom of the filter counter clockwise. A small amount of water may drain. Some shops
may have a coalescing filter already inline. In this case very little moisture may be
present.