PCI-104 PCI Bus Signals
The following are brief descriptions of the PC-104 PCI bus signals.
Address and Data
AD[31:00]
— Address and Data are multiplexed. A bus transaction consists of an address cycle
followed by one or more data cycles.
C/BE[3:0]#
— Bus Command/Byte Enables are multiplexed. During the address cycle, the command
is defined. During the Data cycle, they define the byte enables.
PAR
— Parity is even on AD[31:00] and C/BE[3:0]# and is required.
Interface Control Pins
FRAME#
— Frame is driven by the current master to indicate the start of a transaction and will remain
active until the final data cycle.
TRDY#
— Target Ready indicates the selected devices ability to complete the current data cycle of the
transaction. Both IRDY# and TRDY# must be asserted to terminate a data cycle.
IRDY#
— Initiator Ready indicates the master's ability to complete the current data cycle of the
transaction.
STOP#
— Stop indicates the current selected device is requesting the master to stop the current
transaction.
DEVSEL#
— Device Select is driven by the target device when its address is decoded.
IDSEL[3:0]
— Initialization Device Select is used as a chip-select during configuration.
LOCK#
— Lock indicates an operation that may require multiple transactions to complete.
Error Reporting
PERR#
— Parity Error is for reporting data parity errors.
SERR#
— System Error is for reporting address parity errors.
Arbitration (Bus Masters Only)
REQ[3:0]#
— Request indicates to the arbitrator that this device desires use of the bus.
GNT[3:0]#
— Grant indicates to the requesting device that access has been granted.
System
CLK
— Clock provides timing for all transactions on the PCI bus.
RST#
— Reset is used to bring PCI-specific registers to a known state.
Interrupts
INTA#
— Interrupt A is used to request Interrupts.
INTB#
— Interrupt B is used to request Interrupts only for multi-function devices.
INTC#
— Interrupt C is used to request Interrupts only for multi-function devices.
INTD#
— Interrupt D is used to request Interrupts only for multi-function devices.
Содержание cpuModules CMA24BT
Страница 3: ...Accessing the Analog World www rtd com ISO9001 and AS9100 CMA24BT cpuModules...
Страница 5: ...BDM 610000087 Rev A v...
Страница 6: ...vi CMA24BT cpuModule BDM 610000087 Rev A...
Страница 41: ...BDM 610000087 Rev A Chapter 3 Connecting the cpuModule 31 1 12 V not required for operation of the cpuModule...
Страница 66: ...56 CMA24BT cpuModule BDM 610000087 Rev A...
Страница 87: ...BDM 610000087 Rev A Chapter 4 Using the cpuModule 77...
Страница 88: ...78 CMA24BT cpuModule BDM 610000087 Rev A...
Страница 94: ...84 CMA24BT cpuModule BDM 610000087 Rev A Figure 11 CMA24BTQ1910 Heatsink Edge near PCIe 104...
Страница 96: ...86 CMA24BT cpuModule BDM 610000087 Rev A...
Страница 111: ...BDM 610000087 Rev A Appendix C IDAN Dimensions and Pinout 101...
Страница 112: ...102 CMA24BT cpuModule BDM 610000087 Rev A...
Страница 114: ...104 CMA24BT cpuModule BDM 610000087 Rev A...
Страница 116: ...106 CMA24BT cpuModule BDM 610000087 Rev A...