5.

Refit the CoEx

® 

brewer unit into the machine. Slide the

unit into  place  until it 

"

clicks

into  position.  Refit the

coffee dispense pipe to the brewer outlet as shown.

Ensure  that  both  the  fresh  bean  co

n

t

ai

n

e

r  and  fresh

ground coffee canister are filled with correct product.

Refill if necessary following the procedures outlined in

sub-section 

4

.

5.6 Fresh Bean Canister 

-

B2C 

m

ac

h

ines

.

4

.

7

.

2 Weekly Cleaning Procedure 

VOCE 

The VOCE has a routine cleaning cycle for the CoEx

® 

brewer, with a warning message to indicate 

a  clean  is  "Recommended"  or  "Required".  If  the  "Required"  message  is  ignored  B2C  and 

fresh brew drinks cannot be selected until the brewer is cleaned, using the following procedure

1. 

2

Open the front door of the machine. 

Caution: 

Ensure that a suitable container is placed under the dispense position. Keep 

hands away from the dispense area whilst the cleaning cycle is in operation

Press 

and release button 11 on the service keypad. The 

LCD  will  display  the message 

"Please  Place  Cleaning 

Tablet in 

B

rewer"

Take one cleaning tablet (supplied in packs of 30 

-

CMS 

part  no.  ZC10598000)  and  place  it  into  the  brewer 

piston chamber as shown. 

3.

Press the START/? key on the drink selection keypad to

begin the CoEx

® 

tablet cleaning routine

.

4

.

The cleaning cycle lasts approximately 7 minutes and dispenses approximately 1.8 ltrs

of water through the  dispense head

The LCD  will display the message 

"Cleaning 

in

Progress" 

throughout the cleaning cycle .

..&. 

Safety First! 

Keep hands clear of the brewer mechanism during the cleaning routin

e

.

5

.

When the cleani

ng 

cycle is complete the LCD will display the message 

"C

l

ea

n

i

n

g Cycle

Co

m

p

l

e

t

e". 

Press the 

(Exit) key on the drink selection keypad to return the machine

to standby mode. Empty the water from the conta

i

ner

.

4.8  Brewer Waste Container and Chute 

-

Daily Clean 

1.

Remover the brewer guard.

2.

Remove  the  brewer  waste  container  and  empty  the

contents. Push up and remove the waste chute (a).

3

.

Wash  both the container and chute thoroughly and if

necessary  sanitise  using  the  diluted  bactericidal

solution.

Rinse in clean water

Содержание VOCE

Страница 1: ...Contact us www refreshmentsystems co uk For Service service refreshmentsystems co uk 01274 750 008 For Ingredients ingredients refreshmentsystems co uk 01226 720 482 Cleaning Guide Voce ...

Страница 2: ...Thiscleaningguideis foradviceonly Please referto theoperativemanualfor complete safetyinformationand instructionwhenconsidering any maintenanceonthe machine ...

Страница 3: ...ays Items or surfaces cleaned with this solution must be rinsed in clean water to remove traces of the cleaning agent 4 3 Liquid Destainer Brewer Units Crane Merchandising Systems recommends that a liquid destaining product is used for cleaning the brewer units fitted to VOCE freshbrew machines The product must be used in accordance with the instructions on the product packaging following all heal...

Страница 4: ...move the dispense pipes b from the plastic ro dispense block 3 Turn the whipper base c anti clockwise until it releases first click Remove mixer units d and impeller e Turn the whipper base c anti clockwise again second d click pull the whipper base from the shaft 4 Clean all of the mixing system parts including the steam hoods mixing bowls and dispense pipes thoroughly in the diluted bactericidal...

Страница 5: ...e machine with a clean damp sanitised cloth 4 Refit the whipper system components see sub section 4 5 2 Whipper System for details 4 5 4 Dispense Head Remove the knurled nut a securing the plastic dispense block b to the dispense head assembly Remove the dispense block and clean thoroughly in the diluted bactericidal cleaner solution Rinse the dispense block with clean water and dry thoroughly bef...

Страница 6: ...t the waste water bucket into the machine Ensure that the level detector and overflow pipes are located correctly in the bucket 4 5 8 Dispense Area Components Remove the cup catcher moulding complete with drain pipe Pull out the two spring loaded pins a securing the drip tray and pull and remove the complete drip tray assembly out of its mounting bracket Clean the cup catcher and pipe in the sanit...

Страница 7: ...utton 7 and check that a cup is ejected correctly from the Cup drop unit 2 Press the Park Head button 8 to ensure that the dispense head operates correctly and that the dispense pipes are fitted correctly D m iE fJ 0 ml i I mD D m 1 mm ml 3 Place a suitable container under the dispense head and press the Rinse Flush button 3 The machine will flush the system Check that none of the mixing stations ...

Страница 8: ... mixing bowl and dispense pipe thoroughly in the diluted bactericidal cleaner solution Rinse all components with clean water and dry thoroughly before refitting to machine 4 6 2 Weekly Cleaning Procedure Important It is necessary to carry out the cleaning and maintenance procedure outlined on the following pages on a weekly basis Open the door of the machine Check that the Oltre brewer s are in an...

Страница 9: ...actericidal cleaning agent in accordance with the instructions on the product packaging 2 Carefully place the CoEx brewer unit into the diluted bactericidal solution and clean the unit thoroughly Ensure all coffee ground deposits are removed paying particular attention to the area around the top of the piston and waste chute Remove the unit from the solution and rinse thoroughly with clean water D...

Страница 10: ...elease button 11 on the service keypad The LCD will display the message Please Place Cleaning Tablet in Brewer Take one cleaning tablet supplied in packs of 30 CMS part no ZC10598000 and place it into the brewer piston chamber as shown 3 Press the START key on the drink selection keypad to begin the CoEx tablet cleaning routine 4 The cleaning cycle lasts approximately 7 minutes and dispenses appro...

Страница 11: ...nt of a leak ventilate the area in the vicinity of the bottle to remove all traces of gas and contact your supplier 1 Open the cabinet door and un hook the safety chain from the gas bottle Turn off the gas supply from the bottle 2 Following correct procedures for safe lifting lift the empty cylinder c w regulator out of the machine Carefully undo the locknut using the spanner supplied Remove the r...

Отзывы: