![RSG MCS-32 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/rsg/mcs-32/mcs-32_user-manual_1496636044.webp)
6 DIAG 1 and DIAG2. User Diagnostics.
Pressing the diagnostics button will scroll through several ‘pages’ of information that are reflected on LED's 1 - 16.
The DIAG1 and DIAG2 LED's are the key to which page is currently reflected on the LED's.
DIAG1
DIAG2
DISPLAY
OFF
OFF
High Power Outputs. LEDS 1 - 16 display the state of the outputs.
The following table defines the state of the output:
OFF
The output is not enabled
GREEN The output is enabled (this does not show the flash pattern, only that
the output is active)
AMBER The output is enabled, but the supply voltage has dropped below the
set level (Voltage Dropout)
RED
The output is disabled because of an excessive current fault
GREEN
OFF
Low Power Outputs. LEDS 1 - 16 display the state of the outputs.
The following table defines the state of the output:
OFF
The output is not enabled
GREEN The output is enabled (This does not show the flash pattern,
only that the output is active)
AMBER The output is enabled, but the supply voltage has dropped
below the set level (Voltage Dropout)
RED
OFF
Handset Inputs (RS485 or PWM)
LEDS 1 - 16 display the state of the inputs.
RED
The button is not pressed \ off
GREEN The button is pressed
OFF
GREEN
Positive Inputs (Inputs Connector)
LEDS 1 - 12 display the state of the inputs.
RED
The input is low (0V)
GREEN The input is high (>4V)
OFF
RED
Negative Inputs (Inputs Connector)
LEDS 1 - 12 display the state of the inputs.
RED
The input is low (0V)
GREEN The input is high (>4V)
RSG Engineering Limited
Telephone :
01543 438800
Fax :
01543 438801
Email :
Web :
www.rsg-ontop.com
2:
41
UNIVERSAL CONTROLLER PLUS (MCS-32) USER GUIDE
V3
3
: SYSTEM DESCRIPTION
3
: