Absolute Maximum Ratings
• Supply Voltage : 12/24 Volt
• Supply Current : 40 Amps per power bank
• Standby Current : Typical : 55 milliamps (@13.8VDC, no peripherals attached)
Max : 65 milliamps (@13.8VDC, no peripherals attached)
• Standby Temperature : -20 Deg C – 70 Deg C
• Operating Temperature : -20 Deg C – 50 Deg C
1.2
Power
• 2 x 40Amp DC pins on pluggable connector
- These MUST be fused (fuse rating of 40Amps or less as the application requires).
• 1 x Ground / chassis connections
- If the siren output is going to be used, the ground chassis line should be rated to handle 15 Amps or more
• The Primary Sense line is used to provide power to a single power output. This input should be protected with a fuse rated
at 1 Amp
1.3
Digital Inputs
• 12 x Positive Switched
• 12 x Negative Switched
1.4
Analog Inputs
• Primary battery sense
1.5
Analog Monitoring
• Bank A voltage sense
• Bank B voltage sense
• Internal temperature monitor
• Output channel current monitors
• Siren system current monitor
1.6
Outputs
• 16 x High side current and voltage protected outputs
• 12 X Positive switching Monitor Outputs
• 4 x Positive or Negative switching Monitor Outputs
• 100W siren speaker output
1.7
Communication
• 1 x RS485 Communication
• 1 x Optilink input.
• 2 x CAN Bus 2.0
RSG Engineering Limited
Telephone :
01543 438800
Fax :
01543 438801
Email :
Web :
www.rsg-ontop.com
2:
36
UNIVERSAL CONTROLLER PLUS (MCS-32) USER GUIDE
V3
1
: SPECIFICATION
1
:
Specification