5/22   Rev. E 171551

supplied. See the appliance nameplate for electrical specifications. Failure to use an independent power supply 

of proper capacity can result in a tripped breaker, blown fuse, damage to existing wiring or component failure. 

This could lead to heat generation or fire.

•  The appliance must be properly grounded. This appliance is equipped with a NEMA 5-15P, 5-20P or 6-20P three 

prong grounded plug to reduce the risk of potential electrical shock hazards. It must be connected to a properly 

grounded, independent 3 prong wall outlet. Do not remove the ground prong from the appliance plug and do not 

use and adapter plug. Failure to follow these instructions may result in death, electrical shock or fire.

•  Do not use an extension cord to supply power to the appliance.

•  Do not use the appliance should the power cord become damaged. The power cord should not be altered, 

jerked, pinched, bundled and/or used to hang objects from. Such actions could result in electrical shock or fire. 

To disconnect the unit from power, be sure to grasp and pull on the plug, not the cord.

•  Should the power cord require replacement or service, use only the manufactures replacement parts and be 

sure to connect the green ground wire to the appliance in the same manner the original wire was connected.

•  Do not spray or splash water on the appliance as this may cause short circuits, electrical shock, corrosion or 

failure.

•  Do not make alterations or modifications to the appliance as these could result in electric shock, injury, fire or 

damage to the appliance.

•  Children must be properly supervised around this appliance. 

•  This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 

capabilities or lack of experience and knowledge unless they have been given supervision or instruction 

concerning its use by a person responsible for their safety.

•  Do not climb, stand, or hang on or into the appliance or its components. Death or serious injury could occur or 

the appliance could be damaged.

•  Use caution when opening doors or lids and keep fingers out of pinch points areas.

•  Do not use combustible sprays or aerosols around the appliance as they may catch fire.

•  Do not store gasoline or other flammable substances in or near the appliance as they may catch fire.

•  Keep the area around the appliance clean. Dirt, dust or insects around the appliance could cause harm to 

individuals or damage to the equipment.

•  Do not block air inlets or outlets as this would cause cooling performance to be reduced.

•  Do not overload the storage capacity of the appliance. Allow space between stored items for air flow.

•  Do not load warm or hot items into the appliance. Allow them to cool first or they will raise the cabinet temperature 

and could hasten the deterioration of other foods stored in the cabinet.

•  This appliance is designed for the temporary storage to food products. Use proper sanitation practices.

•  All food products should be covered or stored in sealed containers. Open foods may dry up, pass their smell to 

other foods and increase cross contamination. Some food products may accelerate corrosion of the evaporator 

resulting in failure of the appliance to cool.

•  Component parts must be replaced with manufacturer original equipment parts.

•  The appliance requires an independent power supply of proper capacity that matches the power cord plug 

supplied. See the appliance nameplate for electrical specifications. Failure to use an independent power supply 

of proper capacity can result in a tripped breaker, blown fuse, damage to existing wiring or component failure. 

This could lead to heat generation or fire.

•  The Capsule Pak ECO refrigeration system must be paired with a Master-Bilt or Norlake UL listed ignition 

protected walk-in.

Refrigeration Systems-General Information

Содержание CAPSULE PAK ECO

Страница 1: ...5 22 Rev E 171551 CAPSULE PAK ECO REFRIGERATION SYSTEMS INSTALLATION MANUAL ...

Страница 2: ...spection 3 Safety Information 3 General Installation Instructions 5 8 Set Up and Installation 6 Start Up and Operation 7 Temperature Control 7 Cooler Operation 7 Freezer Operation 7 Condensate Water 8 Loading Product 8 Locating and Mounting Condensing Units 8 Maintenance 9 Maintenance Analysis 10 ...

Страница 3: ...oncealed damage claim Please remember the carrier is your only source for reclaiming freight damages The manufacturer should not be contacted to attempt a return of the product No returns are accepted without a prior authorization SAFETY INFORMATION This manual may contain notices that identify situations that could cause death serious injury and or damage to the appliance or property Please make ...

Страница 4: ...rvision or instruction concerning its use by a person responsible for their safety Do not climb stand or hang on or into the appliance or its components Death or serious injury could occur or the appliance could be damaged Use caution when opening doors or lids and keep fingers out of pinch points areas Do not use combustible sprays or aerosols around the appliance as they may catch fire Do not st...

Страница 5: ...nsideration should be given to accessibility for service Capsule Pak ECO systems are designed for indoor applications only and should be operated in the controlled environment of an air conditioned space The ambient conditions should be at or below 75 F and 55 RH Higher humidity may result in condensate issues If multiple units are located in the same area be sure they do not exhaust hot air into ...

Страница 6: ...tion of air and improve the efficiency of the Capsule Pak ECO SET UP AND INSTALLATION CEILING MOUNTED SELF CONTAINED CAPSULE PAK ECO REFRIGERATION SYSTEM CAUTION This unit uses a flammable refrigerant Use care when handling and operating to avoid damaging the refrigerant tubing or increasing the risk of a leak WARNING This appliance must be installed in accordance with all applicable national stat...

Страница 7: ...ximately 37 F for coolers and 10 F for freezers Refer to the accompanying electronic control manual for detailed instructions on adjusting the control parameters On dual compressor systems there is a programmed delay from the start of the first compressor and the second to reduce the start up power surge on the power supply COOLER OPERATION There is a programmed one minute delay to start the syste...

Страница 8: ... from one will enter into the air intake of others nor where the air flow is toward a wall or obstruction Avoid locating units in restricted spaces where heat will build up and can enter the condenser There must be room around the unit for regular inspection and service We recommend 200CFM in any area where condensing units may be located Air flow should be sufficient to maintain an ambient temper...

Страница 9: ... The Evaporator Coil section is accessible by unlatching and removing the cover Cleaning the Condenser Coil The efficiency of the refrigeration system depends on the unrestricted flow of air through the Condenser Coil Over time dust and debris will collect on the face of the Condenser Coil and will require cleaning A vacuum cleaner with a soft bristle attachment can be used to clean the coil If th...

Страница 10: ...s or replace relay shorted or blown 2 Low voltage to unit 2 Determine reason and correct 3 Improper relay 3 Replace Relay defective or burned out 1 Incorrect relay 1 Check and replace 2 Voltage too high or too low 2 Determine reason and correct Refrigerated space too warm 1 Control setting too high 1 Reset control 2 Refrigerant overcharge 2 Purge refrigerant 3 Dirty condenser 3 Clean condenser 4 E...

Страница 11: ...5 22 Rev E 171551 ...

Страница 12: ...3 5253 Norlake Walk In Installation 800 647 1284 Master Bilt Sales 800 684 8988 Master Bilt Parts Service Thank you for purchasing Refrigerated Solutions Group equipment Please visit the links below to complete your WARRANTY REGISTRATION Information within this publication subject to change without notice For Norlake Equipment norlake com register For Master Bilt Equipment master bilt com register...