Document Number 900-21806 Rev C
9
Operation System Power
CAUTION: NEVER HOOK UP OR DISCONNECT ANY EQUIPMENT
WITH POWER TURNED ON!
The Inspection System requires a steady supply of 120VAC to operate properly.
Before starting of the generator or connecting shore power, make sure that ALL
equipment inside the vehicle has been turned
OFF.
Turn down the controls for
camera power and cable reel speed. After all equipment has been checked,
connect the shore power cord.
If a generator is to be used, allow the generator to warm up for a few
minutes.
Note: Diesel generators use a different control panel that is separate from the
controller power supply. Refer to the appropriate generator operators manual for
starting.
Verify that the voltage and frequency indicators on the controller power supply
are in the green normal zone.
Caution: Before turning on any equipment, plug the keyboard into the data
collection system. Plug the Auxiliary Control Box into the Auxiliary Control
jack on the controller power supply.
Caution: If the voltage or frequency fluctuates into the red zones on the
controller power supply, DO NOT turn on any of the equipment in the truck.
Check shore power or the generator for proper operation, or have them
checked by a qualified technician.
Caution: Route cords away from traffic or wet areas to avoid tripping on
power cords.