1.General Description

Non-Contact Forehead IR Thermometer is specially designed to take
the body temperature of a person regardless of room temperature.

Depending on various skin types and thickness, there may be temperature
difference.

2.Safety Information

•This

 

device

 

must

 

only

 

be

 

used

 

for

 

the

 

purposes described in this

 

instruction manual

•This

 

device

 

must

 

only

 

be

 

used

 

in

 

an

 

ambient

 

temperature

 

range

 

between 10 and 40°C

•Do not expose this thermometer to electic shocks.
•Do

 

not

 

expose

 

this

 

thermometer

 

to

 

extreme

 

temperature

 

conditions

 

of >50°C or <0°C

•Do not use the device in relative humidity higher than 85%.
•Do

 

not

 

use

 

the

 

device

 

near

 

large

 

electromagnetic

 

fields

 

such

 

as

 

found

 

with cordless or cell phones.

•Keep

 

the

 

device

 

away

 

from

 

water

 

and

 

heat,

 

including

 

direct

 

sunlight.

•Do not drop or knock the device, and do not use if damaged.
•It may affect the accuracy of measurements when the forehead is

 

covered by hair, perspiration, cap or scarf.

 

(See Part 10-4)

•Keep

 

the

 

Measuring

 

distance

 

as

 

1cm-10cm

 

(0.39in-3.9in).

 

(See

 

Part

 

10-4)

•When the body infrared thermometer should be left in that room

 

during 15 to 20 minutes before using.

•It may affect the accuracy of measurements when the forehead is

 

covered

 

by

 

perspiration

 

or

 

other

 

factors,

 

please

 

take

 

the

 

temperature

 

behind the ear lobe.

 

(See Part 10-5)

•Clean

 

the

 

glass

 

with

 

a

 

cotton

 

bud

 

lightly

 

moistened

 

with

 

70%

 

alcohol. 

Содержание RS-8806S

Страница 1: ...N17 9RS United Kingdom www rs components com Japan RS Components Ltd West Tower 12th Floor Yokohama Business Park 134 Godocho Hodogaya Yokohama Kanagawa 240 0005 Japan www rs components com U S A Alli...

Страница 2: ...se the device in relative humidity higher than 85 Do not use the device near large electromagnetic fields such as found with cordless or cell phones Keep the device away from water and heat including...

Страница 3: ...wer off Display Resolution 0 1 C 0 1 F Backlight LCD display Measurement Method Rectal Oral Axillary Ear Normal Temp C 36 6 to 38 35 5 to 37 5 34 7 to 37 3 35 8 to 38 Normal Temp F 97 8 to 100 4 95 9...

Страница 4: ...Infrared Thermometer Precision Normal Conditions of Use Display Resolution Operating Temperature Storage Temperature Humidity Rate Power Size Weight 0 1 C 0 1 F 10 to 40 C 50 to 104 F 0 to 50 C 32 to...

Страница 5: ...when inserting new batteries wait between 10 minutes for the warm up of the apparatus and when inserting the new batteries 9 3 If the device is not used for a long time once you turn it on again the d...

Страница 6: ...human being For this use the Body mode Measurement range for Body mode 32 to 42 5 C 86 to 108 F You can also use the Non contact Body Infrared Thermometer to measure the temperature of an area or an o...

Страница 7: ...om dust and direct sunlight 13 Troubleshooting If you happen to have one of the following problems while using the non contact forehead IR thermometer please refer to this breakdown service guide to h...

Страница 8: ...etic interference Avoid using the device in high electromagnetic environment The MEDICAL DELECTRICAL EQUIPMENT needs special precautions regarding EMC and needs to be installed and put into service ac...

Страница 9: ...magnetic immunity Compliance level 3 Vrms Recommended separation distance d 1 2 p Radiated RF lEC 61000 4 3 where P is the maximum output power rating of the transmitter In watts W according to the tr...

Страница 10: ...W 0 01 0 1 1 10 100 Separation distance according to frequency of transmitter m 150 kHz to 80 MHz 0 12 0 38 1 2 3 8 12 Table 206 Recommended separation distances between portable and mobile RF commun...

Отзывы: