EN - 8

 

ACA

 

Resistance

 

 CAT.

.600V 

with respect to  

earth for the jaw. 

Tactile Barrier for 

hand guard. 

 Do not hold 

the meter across  

the Tactile Barrier. 

Содержание ICM A5

Страница 1: ...Instruction Manual ICM A5 Clamp Meter EN DE ES IT FR ...

Страница 2: ...ur fingers behind the finger guards Remove the test lead from the instrument before opening the battery cover or instru ment case Always use the correct terminals switch position and range for measurements Verify the instrument is operating correctly by measuring a known voltage before use If in doubt have the instrument serviced Do not apply more than the rated voltage as marked on the instrument...

Страница 3: ...the function rotary switch in Ω A position If possible do not work alone so assistance can be given if required Do not expose the instrument to extremes of temperature or high humidity The following symbols may appear on the instrument and in this Instruction Manual Risk of electric shock Refer to Instruction Manual Alternating Current ac Battery Earth Equipment protected throughout by double or r...

Страница 4: ...fied personnel This instrument should be calibrated yearly or more frequently if used in harsh conditions or if it is suspected of being inaccurate For calibration and repair contact RS Components the address is given at the end of these instructions Cleaning Periodically wipe the case with a damp cloth and detergent Do not use abrasives or solvents ...

Страница 5: ...EN 5 Power On Off Auto Power Off The instrument will automatically turn off approximately 10 minutes after the last operation AC V DC V ...

Страница 6: ...ion of the function rotary switch including the OFF position 2 Remove the test leads from the instrument as they are not used for the VoltSense test 3 Press and hold the VoltSense button The LCD display will go blank a tone will sound and the red LED will illuminate momentarily to confirm the instrument is operational ...

Страница 7: ...on down and move the instrument over the area where detection is required The buzzer will sound and the LED will illuminate when a live conductor is detected Release the VoltSense button to return to normal operation Diode Continuity ...

Страница 8: ...EN 8 ACA Resistance CAT Ⅳ 600V with respect to earth for the jaw Tactile Barrier for hand guard Do not hold the meter across the Tactile Barrier ...

Страница 9: ...dicator appears on the LCD replace the batteries with the type given in the specifications WARNING Disconnect the test leads from the circuit and the instrument before removing the battery cover Refer to the following figure to replace the batteries ...

Страница 10: ...ibration One year calibration cycle Operating temperature 0 C to 30 C 32 F to 86 F 80 RH 30 C to 40 C 86 F to104 F 75 RH 40 C to 50 C 104 F to 122 F 45 RH Storage temperature 20 to 60 C 4 F to 140 F 0 to 80 RH with batteries removed from the instrument Dimensions W x H x D 54mm x 193mm x 31mm Weight 280g including battery Accessories Battery installed Carrying case and User manual Measurement Cate...

Страница 11: ...ion boards junction boxes socket outlets and wiring and cables in the fixed installation Measurement Category lV is for measure ments performed at the source of the low voltage installation Examples include measurements on primary overcurrent protection devices and electricity meters Operating altitude 2000m 6562 ft Conductor Size 16mm diameter Pollution degree 2 EMC EN 61326 1 Shock vibration Sin...

Страница 12: ...olts Over voltage protection DC 1000V AC 750V Input Impedance 2 MΩ less than 100pF CMRR NMRR Common Mode Rejection Ratio Normal Mode Rejection Ratio VAC CMRR 60dB at DC 50Hz 60Hz VDC CMRR 100dB at DC 50Hz 60Hz NMRR 50dB at DC 50Hz 60Hz AC Conversion Type Average sensing rms indicating AC Current Function Range Accuracy A 50 60Hz 0 0 200 0A 3 0 3 dgt Overload protection 400 Arms AC Conversion Type ...

Страница 13: ...gt rolling 2 10 dgt rolling Diode Check and Continuity Resolution Accuracy 1 mV 1 5 0 05 V For 0 4V 0 8V Max Test Current 1 5mA Max Open Circuit Voltage 3V Overload Protection 600Vrms Continuity Internal beeper activates if the resistance of the circuit under test is less than 50Ω It will then turn off if the resistance is increased beyond 250Ω Response time is approximately 0 25 1 sec ...

Страница 14: ...tion contamination or abnormal conditions of operation or handling Any implied warranties arising out of the sale of this product including but not lim ited to implied warranties of merchantability and fitness for a particular purpose are limited to the above RS Components shall not be liable for loss of use of the instru ment or other incidental or consequential damages expenses or economic loss ...

Страница 15: ...EN 15 ...

Страница 16: ...EN 16 ...

Страница 17: ...n Road Shanghai 200001 China www rs components com Europe RS Components Ltd PO Box 99 Corby Northants NN17 9RS United Kingdom www rs components com Japan RS Components Ltd West Tower 12th Floor Yokohama Business Park 134 Godocho Hodogaya Yokohama Kanagawa 240 0005 Japan www rs components com U S A Allied Electronics 7151 Jack Newell Blvd S Fort Worth Texas 76118 U S A www alliedelec com South Amer...