Digital Soldering Station, Model № DS80

7

Digital Soldering Station, Model № DS80

6. Manual standby function

This function enables the device to cool down to “T1” 

mode when the button is pressed which will then 

be indicated by the “Standby” segment in the LCD 

display (see Figure 3). Pressing “T1” again will 

 

re-activate the previous set point temperature. 

Figure 3

 

The station is shipped with the standby function 

disabled. To enable the function, press “T1”, “T2”, 

“T3” together to switch the DS80 into programming 

mode. The “Prog” segment will be indicated on the 

display (see Figure 4).

Figure 4

Now press the “T1” key. An arrow will indicate that 

the standby function is enabled; (see Figure 5). 

 

The display will revert back to normal mode after 

three seconds.

Figure 5

7. Timer-controlled standby function

This enables the iron to automatically cool down 

to the standby temperature after a set period of 

time since the last key was pressed. The device 

is shipped with the timer-controlled standby 

function disabled. To enable, switch the DS80 to 

programming mode as shown above and press and 

hold the “T1” key. Use the “+”/”-“ keys to adjust the 

timeout; (see Figure 6). Maximum time is 9 hours 

and 55 minutes. 

Note: 

The programmed timeout data will only 

become valid after switching the solder station off 

and then back on.

Figure 6

8. Automatic power-off function

This enables the device to automatically switch 

off after a set period of time since the last key was 

pressed. The device is shipped with the automatic 

power-off function disabled. To enable, switch the 

 

DS80 to programming mode as shown above and 

press and hold the “T2” key. Use the “+”/”-“ keys 

to adjust the power-off timeout; (see Figure 7). 

Maximum time is 9 hours and 55 minutes. 

Note:

 The programmed power-off data will only 

become valid after switching the solder station off 

and then back on.

Figure 7

9. Disabling the “Power” bar-chart

Switch the DS80 to programming mode as shown 

above and press the “T2” key. The arrow segment 

above this key will disappear; (see Figure 8). 

Pressing the “T2” key again will re-enable the 

 

bar-chart display.

Figure 8

10.  Switching between °C (Celsius) 

 

and °F (Fahrenheit)

Switch the DS80 to programming mode as shown 

above and press the “T3” key. The arrow segment 

above this key will disappear; (see Figure 9). 

Pressing the “T3” key again will switch the display 

back to °C and the arrow will reappear.

Figure 9

11. Static Bonding / EPA Point

Socket for 4mm ‘Banana’ Plug. Provided for critical 

applications, where a grounding link is required to 

equalise the soldering station potential to the working 

area, to minimise any potential voltage difference 

between the soldering tip and circuit board. For 

suitable 1.8m long coiled grounding cord with 4mm 

Banana plug and 10mm Stud, see RS 552-898.

 

(EPA = Equalised Potential Area)