RPS micromag series Скачать руководство пользователя страница 24

- 24 -  

M

ICRO

M

AG

-OP-EN

MAINTENANCE

DAILY MAINTENANCE:

1.  Remove the clean Pads or Brushes.  Never use 

soiled Pads when cleaning.  Replace Pads when they 
become packed with residue.

2.  Remove and clean debris from the fl oat shut-off screen 

and Drain Saver located inside the Recovery Tank.

3.  Drain and rinse Tanks thoroughly and fl ush out 

Solution Feed to deck.

4.  Inspect Vacuum Hose for any objects obstructing the 

air fl ow.

5.  Raise Squeegee and wipe Blades with a clean cloth.  

Store Squeegee in the raise position to prevent 
damage or setting of the Blades.

6.  Wipe down machine if needed.  Use a non-abrasive, 

non-solvent cleaner or a clean damp cloth.

7.  Recharge the Batteries if needed.

WEEKLY MAINTENANCE:

1.  Check Battery water level in each cell of the Batteries 

and fi ll as needed.  Always use distilled water to refi ll 
Batteries.  Batteries should be fi lled approximately 

3

4

'' to 1'' above the plates.  Overfi lling will cause 

the batteries to leak during charging.  The charging 
process creates gas bubbles inside the Battery, which 
effectively increases the volume of the electrolyte.

2.  Clean Battery tops to prevent corrosion.

3.  Flip Scrubdeck brushes / pads.

4.  Drain and rinse Tanks thoroughly.  To thoroughly fl ush 

out any solution chemicals in solution line valves, refi ll 
Solution Tank with a few gallons of warm, clean water 
and run the machine until Tank is empty.

MONTHLY MAINTENANCE:

1.  Check Scrubdeck and Squeegee lifting cables for wear 

and spring tension.

2.  Check machine for water leaks and loose nuts and 

bolts.

3.  Check to see if battery cables are tightened.  Tighten, 

if needed, 8-10 ft/lb MAX.

4.  Grease caster swivel and Squeegee pivot point.

YEARLY MAINTENANCE:

Call your local dealer for yearly maintenance.

STORING MACHINE:

1.  Be sure to fl ush the Tanks out completely.  To 

thoroughly fl ush out any solution chemicals in solution 
line and valves, refi ll Solution Tank with a few gallons 
of warm clean water and run machine until Tank is 
empty.

2.  Open the Recovery Tank lid to promote air circulation.

3.  Raise Brush/Pad and Squeegee.

CHECKING BATTERY SPECIFIC GRAVITY:

Use a hydrometer to check the Battery specifi c gravity.
Checking Gravity:
• Hydrometer
• Battery

NOTICE

Do not take readings immediately after adding distilled 
water.  If water and acid are not thoroughly mixed, the 
reading may not be accurate.

Check the hydrometer against this chart

SPECIFIC GRAVITY 

8

0

°

F (27

°

C)

BATTERY 

CONDITION

1.265

100% Charged

1.225

75% Charged

1.190

50% Charged

1.155

25% Charged

1.120

Discharged

NOTICE

If the readings are taken when the  battery electrolyte 
is any temperature other than 80

°

F(27

°

C), the reading 

must be temperature corrected.  To fi nd the corrected 
specifi c gravity reading when the temperature of the 
battery electrolyte is other than 80

°

F(27

°

C): add (+) to 

the specifi c gravity reading 0.004 (4 points), for each 
10

°

F(6

°

C) above 80

°

F(27

°

C).  Subtract (-) from the 

specifi c reading 0.004 (4 points), for each 10

°

F(6

°

C) 

below 80

°

F(27

°

C).

WATER LEVEL SHOULD BE 
1/8'' ABOVE PLATES

Содержание micromag series

Страница 1: ...Pad Assist 20 Disk Pad Assist www rpscorporation com 1711 South Street Racine WI 53404 USA 800 450 9824 001 262 681 6470 VERSION 16 055 2016 RPS Corporation MICROMAG OP EN Read the Operators Manual b...

Страница 2: ...you the different machine controls and features MACHINE SETUP Tells you how to setup machine from un crating to installing Squeegee and Brushes MACHINE OPERATION Section is to familiarize the operator...

Страница 3: ...ub Only 15 Vacuum Only 15 One Pass Scrubbing Traction 16 Scrub Only 16 Vacuum Only 16 Adjust Solution Flow 17 Draining Solution Tank 17 Draining Recovery Tank 17 Open Recovery Lid 17 Flush Recovery Ta...

Страница 4: ...HINE Unless you are trained and authorized to do so Unless you have read and understood this Operator s Manual On surfaces with greater than a 2 grade unless this machine is equipped with a functional...

Страница 5: ...emove paint over or destroy warning decals If warning decals become damaged call 1 262 681 3583 for free replacements WARNING Dress safely Do not wear a neck tie scarf or any loose or dangling clothin...

Страница 6: ...M CHARGER PROVIDED WITH THE MA CHINE ALWAYS DISCONNECT THE BATTERY BEFORE SERVICING THE MACHINE REFER TO MANUAL OR CALL 011 262 681 3583 DANGER EXPLOSION RISK EXPLOSIVE HYDROGEN GAS FORMS WHEN BATTERI...

Страница 7: ...ENCY SHUT OFF SWITCH OPTIONAL Shuts OFF the machine in case of emergency 11 HANDLE BAR Adjustable Handlebar 12 ADJUSTABLE HANDLE BAR LOCK Pull out to adjust Handlebar and release to lock the Handlebar...

Страница 8: ...6 SOLUTION FLOW SHUT OFF VALVE Meters solution rate GPM 7 SOLUTION FLOW VALVE Turns solution ON OFF Turns off when motor stops 8 PAD ASSIST DRIVE ADJUSTMENT KNOB Adjusts amount of offset being applie...

Страница 9: ...Height of wheels adjust to height of Squeegee 6 SQUEEGEE PITCH ADJUSTMENT Adjusts pitch of Squeegee Deflection should be even across entire blade 7 SQUEEGEE BLADE Recovers dirty water from floor to be...

Страница 10: ...Turn all switches to the OFF position and remove Key if machine is equipped with Optional Key Switch 2 Attach all Battery Cables as shown below 3 Turn ON main Key Switch and check the Battery Conditi...

Страница 11: ...djusted just right with good deflection across the entire rear Blade SEE BELOW REMOVING SQUEEGEE 1 With the Squeegee in the up position turn machine power off 2 Disconnect Vacuum Hose A from Squeegee...

Страница 12: ...SEE BELOW 5 With Brushes locked into place tip machine back down to a level surface INSTALLING DRIVER PADS 1 Select the correct Pads that best meet your cleaning application needs Consult your local d...

Страница 13: ...e by pulling down from the corners SEE BELOW 5 Once Grip Face is clear of any Pads place Pad want ed for application centered on the Grip Face This will leave a overhang on all sides SEE BELOW 6 Press...

Страница 14: ...down To shut the solution OFF completely just release the Drive button or use dash mounted switch 2 Keep an eye on the clear Vacuum Cover to make sure that there is not any foamy buildup in the Recove...

Страница 15: ...e Reverse switch H back towards the Handlebar The reverse speed is set to approximately 50 of the forward speed 8 To stop the machine shutoff Scrubdeck switch F and Vac Motor D SCRUB ONLY 1 Turn on ma...

Страница 16: ...ttons G SCRUB ONLY 1 Turn on machine Power Switch A while making sure the Speed Control Knob B is at a lower setting 2 Lower Scrubdeck head to the floor by pressing the Scrubdeck Switch on the Control...

Страница 17: ...OVED locations only 2 Rinse out Tank and Solution Flow system with clean water DRAINING RECOVERY TANK Always empty Recovery Tank when refilling the Solution Tank You can refill the Solution Tank while...

Страница 18: ...id open and Tank fully drained 1 Remove 2 Squeegee Intake Hose A from Drain Saver strainer B SEE BELOW 2 Remove stainless screen and dispose of debris 3 Rinse screen with fresh water from the outside...

Страница 19: ...ip Tank Back carefully until supported by strap as well as the Rubber Grommets on the Handlebar SEE BELOW SQUEEGEE UP 1 To raise the Squeegee off the floor rotate Squeegee Lift Lever A counter clockwi...

Страница 20: ...peners E that are available to quiet machine operation SOLUTION FILTER The solution system has an Inline Filter A to filter out cleaning solution prior to scrubbing SEE BELOW CLEANING SOLUTION FILTER...

Страница 21: ...ne It is designed to charge the Batteries at the appropriate rate If you must use a different charger disconnect the Batteries before charging to avoid damage to the electronic speed controller EXTERN...

Страница 22: ...e to charge the batteries of this machine It is designed to charge the batteries at the appropriate rate If you must use a different charger disconnect the batteries before charging to avoid damage to...

Страница 23: ...wear rings or metal wrist watches when servicing this machine as they can cause an electrical short circuit which can cause serious burns INSPECTION AND CLEANING Keep Batteries clean and dry from res...

Страница 24: ...1 Check Scrubdeck and Squeegee lifting cables for wear and spring tension 2 Check machine for water leaks and loose nuts and bolts 3 Check to see if battery cables are tightened Tighten if needed 8 1...

Страница 25: ...Particulate Dark BATTERY 2 WATER LEVEL Overfilled Full Low Dry CLEAN BATTERY TOPS CHECK BATTERY CABLE AND TERMINAL CONDITION NOTES PAD CONDITION SCRUB BRUSH FIBER LENGTH ROTATED BRUSHES DISK PAD DRIVE...

Страница 26: ...AIN SAVER VACUUM FLOATS SCREENS VACUUM HOSES SOLUTION HOSES BLADE RETAINERS HARDWARE SQUEEGEE WHEELS BRUSH SKIRTS CASTER CONDITION DRIVE WHEELS CONDITION COMMENTS SERVICING DISTRIBUTOR _______________...

Страница 27: ...ze 17 or 20 DISK PADS DISK LEVEL COLOR Super Black 422BB Very High Black Black 422B High Black Brown 422BR High Brown Green 422G Medium Green Blue 422BL Moderate Blue Red 422R Moderate Red White 422W...

Страница 28: ...rdware NOTICE Squeegee Assemblies complete listed above all come with Linatex blades NOTICE Size is stamped into the top of the painted steel squeegee body on all squeegee s NOTICE The 26 squeegee is...

Страница 29: ...BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK...

Страница 30: ...RPS Corporation 2016 1711 South Street Racine WI 53404 www rpscorporation com www factorycat com www tomcatequip com Tel US 800 634 4060 Tel Int 001 262 681 3583...