background image

In this screen it is possible to enable or disable 

watering programmes using the keys 

[+] 

and 

[-]

: keep one of the two keys pressed until the 

desired mode is displayed.

Select the mode 

ON/OFF

 and press 

CONFIRM

 to enter the watering programme 

setting procedure (section 2.3) or 

NEXT

 to exit 

from the programming procedure.

By selecting 

OFF

, the programme setting is 

disabled and the control panel, is in stand-by 

mode. If 

ON

 is selected the programme is 

enabled. 

CONFIRM

: confirms preset and passes to the 

following item (rate/cal.)

NEXT

exits the programming procedure.

[+]

ON/OFF

 setting (cycle check). 

[-]

OFF/ON

 setting (cycle check).

ENABLING WATERING 

PROGRAMMES

Programmatore_serie_DIG_GB.indd   14

18/07/12   15.06

Содержание DIG Series

Страница 1: ... DIG series controller Programming instructions ogrammatore_serie_DIG_GB indd 1 18 07 12 15 0 ...

Страница 2: ...isplay and four function keys After the battery has been inserted all the icons on the display are illuminated for five seconds to check the correct operation of the LCD when this check is completed the main screen with the clock and battery charge indicator is displayed section 2 1 1 1 USER INTERFACE ogrammatore_serie_DIG_GB indd 2 18 07 12 15 0 ...

Страница 3: ... the programming stage Decrease of value in the programming stage NOTE Different functions associated with each key are specified in the detailed description of the user interface in the following sections SERVICE NOTE 1 To cut down the electrical consumption of the control panel energy saving mode the display turns off automatically if no keys are pressed within one minute 2 To turn on the displa...

Страница 4: ...amming and in the default screen Icon battery on indicates the battery is charged Flashing icon indicates the battery is flat and must be replaced RAIN SENSOR Displays the status of the outdoor rain sensor if any and is always visible the icon is active during programming and in the default screen Icon on indicates that the ground is wet watering cancelled Icon off indicates the ground is dry wate...

Страница 5: ...ts to flash together with the irrigator the item to be set flashes on the numerical display hours or minutes or AM PM IRRIGATOR Used in three different ways during programming to indicate the zone which is being programmed in the manual procedure to indicate the valve is open or closed and in the default screen to indicate that watering is under way Irrigator off valve closed watering not under wa...

Страница 6: ...y hours minutes AM PM or calendar CALENDAR Used in the programming procedures of the clock or watering programmes to indicate that the weekly calendar is being set When the icon flashes in conjunction with the item being programmed the week day is referenced MANUAL Used in the control procedures of the manual functions Icon off manual functions are not active Icon flashing entry in the procedures ...

Страница 7: ... checked After five seconds the main screen with the clock and battery charge indicator is displayed and the main menu check is enabled After the battery has been installed all icons on the display light up in check mode for five seconds During this stage the function keys are disabled 2 1 MAIN MENU CHECK DISPLAY FUNCTIONAL CHECK AM PM In the default screen it indicates the time of day Icon AM on ...

Страница 8: ...RG flashes use the key CONFIRM to enter the watering programme procedure section 2 3 or NEXT to pass to the following function MAN In this screen the keys and are disabled MAIN DEFAULT SCREEN WATERING PROGRAMMES When NEXT is pressed the icon CLOCK starts to flash press CONFIRM to enter the clock programming procedure section 2 2 or NEXT to pass to the following function PRG In this screen the keys...

Страница 9: ...lock and battery charge state is displayed In this screen the keys NEXT and CONFIRM are disabled 2 2 PROGRAMMING THE CLOCK AND THE WEEEKLY CALENDAR From the main menu it is possible to access the programming procedure of the clock and weekly calendar NOTE the icons printed in grey indicate that they are blinking The rain sensor and the battery icons are on or off according to the actual charged st...

Страница 10: ...g item CONFIRM confirms the value and pass to the following item minutes NEXT disabled increases and decreases the parameter to be programmed When the display of the minutes flashes use keys and to set the desired value Press CONFIRM to pass to the following item CONFIRM confirms the value and pass to the following item PM AM NEXT disabled increases and decreases the parameter to be programmed PRO...

Страница 11: ...M to end the procedure CONFIRM confirms the value and exit from the procedure default screen NEXT disabled increases and decreases the value to be programmed PROGRAMMING PM AM PROGRAMMING THE WEEKLY CALENDAR The main screen is displayed when the clock programming procedure is completed CONFIRM enters the clock programming procedure NEXT main menu check In this screen the keys and are disabled HOW ...

Страница 12: ...ain menu screen section 2 1 the watering programmes setting procedure can be selected by pressing CONFIRM when the icon PRG flashes The first parameter to be set using the keys and is the programme mode off to disable watering programme disabled ON to enable the programme watering cycles enabled 2 3 WATERING PROGRAMMES NOTE the icons printed in grey indicate that they are blinking The rain sensor ...

Страница 13: ...cedure for the watering programme the watering enable screen is displayed CONFIRM enters the programme enable procedure NEXT passes to the following function in the main menu MAN In this screen the keys and are disabled CREATING WATERING PROGRAMMES ogrammatore_serie_DIG_GB indd 13 18 07 12 15 0 ...

Страница 14: ...g procedure section 2 3 or NEXT to exit from the programming procedure By selecting OFF the programme setting is disabled and the control panel is in stand by mode If ON is selected the programme is enabled CONFIRM confirms preset and passes to the following item rate cal NEXT exits the programming procedure ON OFF setting cycle check OFF ON setting cycle check ENABLING WATERING PROGRAMMES ogramma...

Страница 15: ... h48 h72 h96 or the weekly calendar mode CAL to enable watering on the programmed days 1 7 When the watering programme repetition mode is set the watering start programmes can be defined NOTE the icons printed in grey indicate that they are blinking The rain sensor and the battery icons are on or off according to the actual charged state of the battery and the ground conditions wet or dry ogrammat...

Страница 16: ...y programming if the calendar mode is selected section 2 3 3 To quit the programming procedure and return to the main menu section 2 1 press and keep NEXT pressed for three seconds CONFIRM confirms the mode and passes to next programming step NEXT exits the programming procedure check of modes h24 h48 h72 h96 CAL check of modes h24 h48 h72 h96 CAL SELECTING THE RATE MODE OR CALENDAR MODE ogrammato...

Страница 17: ...tering start programmes according to the selected period h24 watering rate every 24 hours h48 watering rate every 48 hours h72 watering rate every 72 hours h96 watering rate every 96 hours CAL weekly calendar mode By selecting the calendar operating mode CAL the programme can be changed only on the programmed days by setting the weekly calendar ogrammatore_serie_DIG_GB indd 17 18 07 12 15 0 ...

Страница 18: ...nfirms the day and pass to the following item ON OFF NEXT exits the programming procedure keep it pressed for 3 sec keys are disabled SELECTING THE WEEKLY CALENDAR DAY NOTE the icons printed in grey indicate that they are blinking The rain sensor and the battery icons are on or off according to the actual charged state of the battery and the ground conditions wet or dry ogrammatore_serie_DIG_GB in...

Страница 19: ...The irrigator icon lights up when ON is selected To pass to the start programme definition section 2 3 4 press NEXT after ON OFF programming of day number 7 CONFIRM confirms the day and passes to the following item ON OFF NEXT exits the programming procedure keep it pressed for 3 sec ON OFF mode selection cyclic check OFF ON mode selection cyclic check ON OFF SETTING ON THE SELECTED DAY ogrammator...

Страница 20: ...tering data section 2 3 5 CONFIRM confirms the start and passes to the following item ON OFF NEXT exits the programming procedure keep it pressed for 3 sec selects the start programme number selects the start programme number SELECTING A START PROGRAMME NUMBER NOTE the icons printed in grey indicate that they are blinking The rain sensor and the battery icons are on or off according to the actual ...

Страница 21: ...hen the desired period has been selected press CONFIRM to enter the minute programming procedure keep the key pressed for at least 10 secs to save the data the active programme and to exit from the procedure To quit the procedure without saving the data press NEXT for three seconds SETTING WATERING TIMES HOURS NOTE the icons printed in grey indicate that they are blinking The rain sensor and batte...

Страница 22: ...y set zero is displayed on the numerical display When the desired period has been selected press CONFIRM to enter the time programming procedure keep the key pressed for approximately 10 secs to save the data and exit from the procedure To quit the procedure without saving the data press NEXT for three seconds CONFIRM confirms the value and passes to the following item START TIME NEXT exits the pr...

Страница 23: ... CONFIRM to enter the minute programming procedure keep the key pressed for 10 secs to save the data and exit from the procedure To quit the procedure without saving the data press NEXT for three seconds CONFIRM confirms the value and passes to the following item MINUTES NEXT exits the programming procedure without data backup sets the start time 1 12 sets the start time 1 12 ogrammatore_serie_DIG...

Страница 24: ...CONFIRM to enter the AM PM programming procedure keep the key pressed for approximately 10 secs to save the data and exit from the procedure To quit the procedure without saving the data press NEXT for three seconds CONFIRM confirms the value and passes to the following item AM PM NEXT exits the programming procedure without data backup sets minutes of start time 00 59 sets minutes of start time 0...

Страница 25: ...ithout data backup selects PM icon PM on selects AM icon AM on NOTE ON PROGRAMMING MODES 1 Watering starts P01 P10 need not be programmed in chronological order the control panel performs the watering cycle as nearer as possible to the real time by temporarily creating an order in automatic mode 2 The watering starts P01 P10 need not be programmed following a chronological order some positions may...

Страница 26: ... the manual procedure CONFIRM enters the clock programming procedure NEXT passes to the following function of the main menu MAN In this screen the keys and are disabled MANUAL FUNCTIONS NOTE the icons printed in grey indicate that they are blinking The rain sensor and the battery icons are on or off according to the actual charged state of the battery and the ground conditions wet or dry ogrammato...

Страница 27: ... quit the manual function control procedure and return the main menu section 2 1 press NEXT CONFIRM confirms the selection and passes to the following item TIME NEXT exits the manual function control selects ON OFF mode cyclic check selects ON OFF mode cyclic check MANUAL WATERING ON OFF SETTING ogrammatore_serie_DIG_GB indd 27 18 07 12 15 0 ...

Страница 28: ...press CONFIRM to enter the minute programming procedure To quit programming without saving the data press NEXT CONFIRM confirms the value and passes to the following item MINUTES NEXT exits the programming procedure without data backup sets the watering time 0 to 11 hours sets the watering time 0 to 11 hours MANUAL SETTING OF WATERING TIME HOURS ogrammatore_serie_DIG_GB indd 28 18 07 12 15 0 ...

Страница 29: ...o enable the opening pulse of the solenoid valve and display the on status following screen To quit programming without saving the data press NEXT CONFIRM confirms the value and passes to the following item EV ON NEXT exits the programming procedure without data backup sets the watering time 00 to 59 minutes sets the watering time 00 to 59 minutes MANUAL SETTING OF WATERING TIME MINUTES ogrammator...

Страница 30: ...NEXT disabled disabled disabled SERVICE NOTES Watering is active until the set manual time has elapsed to close the solenoid valve and stop watering return to the manual function and select OFF If the manual watering is added to an automatic cycle P01 P10 the manual cycle will be performed first If CONFIRM is pressed with the time set to zero the valve does not open and the system will be as progr...

Страница 31: ...grammed automatic cycle 2 If a watering start has been programmed during a manual opening the automatic watering cycle will not operate 3 In manual mode it is possible to disable the programmed watering cycle during operation ogrammatore_serie_DIG_GB indd 31 18 07 12 15 0 ...

Страница 32: ...RPE s r l Via S Ambrogio 3 22070 Carbonate CO Italy Tel 39 0331 832515 Fax 39 0331 832501 info rpesrl it www rpesrl it rpe 07 2012 ogrammatore_serie_DIG_GB indd 32 18 07 12 15 0 ...

Отзывы: