TYPICAL SYSTEM SCHEMATICS (CONT.)
INSTALLATION
1) Install a new cold air return from existing ducts to the solid fuel furnace.
2) Install a back draft damper (air flow baffle) between the solid fuel furnace hot air outlet and the existing furnace hot air plenum.
3) Install a back draft damper (air fl ow baffl
e) between the existing furnace and the existing hot air plenum.
A) The back draft damper MUST be installed above any air conditioning “A” coils.
B) The back draft damper MUST be installed below the connection to the solid fuel furnace back draft damper.
For your safety, turn off electrical power supply at service entrance panel before
making any electrical connections to avoid possible electric shock hazard. Failure to do
so can cause severe personal injury or death.
***COMPLEX SYSTEMS SHOULD BE DESIGNED BY A HEATING PROFESSIONAL.***
DANGER