19
NOTE: Electrical wiring must be installed by a
licensed electrician.
Caution: Disconnect remote controls if you are
absent for extended time periods. This will
prevent accidental fireplace operation.
For Standing Pilot Ignition Wiring
Appliance Requirements
This appliance
DOES NOT
require 110-120 VAC
to operate.
WARNING
DO NOT CONNECT 110-120 VAC TO
THE GAS CONTROL VALVE OR THE
APPLIANCE WILL MALFUNCTION AND
THE VALVE WILL BE DESTROYED
.
Optional Accessories
Optional fan and remote control kits require that 110-
120 VAC be wired to the factory installed junction box
before the fireplace is permanently installed.
NOTE:
When installing a blower, remove the glass
and remove the two screws holding the air chute in
place. Remove the air chute and install the blower.
YOU MUST REPLACE THE AIR CHUTE AFTER
INSTALLATION!
Remote Wall Switch
Position the remote wall switch in the desired
position on a wall. Run a maximum of 25 feet (7.8 m)
or less length of 18 A.W.G. minimum wire and
connect it to the fireplace ON/OFF switch pigtails.
WARNING: DO NOT CONNECT 110-120
VAC TO THE REMOTE WALL SWITCH
OR THE CONTROL VALVE WILL BE
DESTROYED.
CAUTION
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.
Figure 12. Standing Pilot Ignition Wiring Diagram
Step 9
Wiring the
Fireplace
!
!