14.6 Manual activation of the pellet loading system
Upon first ignition, or if the tank is completely empty, once the pellets have been loaded into the
tank, it is possible to manually activate the loading system so that the pellets fill the circuit correctly:
a) Use the arrow keys to go to the set-up menu and press the key ;
b) Select the password “7” with the key and confirm with the key;
c) Select the submenu
[31]
and confirm with the key;
d) Select password “54”
e) Hold down the key to activate the manual loading system.
It is only possible to activate this procedure with the stove off and completely cold.
15 ALARM MANAGEMENT
If an anomaly occurs in the operation, the following procedure is activated:
1) acoustic alarm (beep);
2) one of the following system LEDs lights up:
;
3) if the anomaly concerns an error, the stove will switch off.
Press and hold the "cancel” key to display the error code:
CODE
ERROR/WARNING
DESCRIPTION
POSSIBLE CAUSES
LED
E001
Defective control panel
Defective control panel
E002
Remote control communication
signal error
Defective control panel
E004
Communication error
Connection cable between board and control
panel interrupted or disconnected.
If it appears during the configuration change,
ignore this error
E101
Ignition failure error
Insufficient pellets
Pellet quality
Faulty ignition system
Dirty burn pot
E105
Pellet probe alarm
Pellet probe disconnected or faulty
E108
Pressure or thermal safety error
Dirty fume evacuation system
Worn sealing gaskets
Insufficient combustion air
Problems of overheating of the pellet tank
E106
Temperature probe malfunction
Sensor(s) connected to T01 (ref. wiring
diagram)
Defective air probe
Overheating problems
E110
Temperature probe malfunction
Sensor(s) connected to T02 (ref. wiring diagram)
Defective air probe
E111
Fume probe malfunction
Sensor(s) connected to T03 (ref. wiring
diagram)
Defective flue gas temperature probe
A002
Scheduled maintenance notification
(flashing icons)
Periodically, the stove requires maintenance by
a specialist technician
A004
Low battery
The back-up battery (mod. CR2032) on the
electronic board is low *
A005
Hall sensor malfunction
Hall sensor on fumes fan disconnected or faulty
----
Stove cleaning
Combustion chamber, burn pot or dirty fume
evacuation.
Detached or blocked pressure detection tubes.
Blocked combustion air intake.
----
Ignition failure error
Faulty ignition resistance
Worn gaskets; Incorrect burn pot position