4. Assembly of the skimmer
After a complete clean, reassemble the skimmer accord-
ing to the following instructions:
Start by reassemble the pump first. Carefully insert the ro
-
tor in the engine block.
Tighten the four screws until the gap between
housing cover and motor block is closed.
DO NOT overtighten the screws.
Fix the pump on the lower bottom plate and place the
skimmer body.
Caution:
pay attention to the correct seat
of the cable of the pump. Insert the bottom plate screws
and tighten moderately. Also please do
not
work with too
much force.
At the base of the injection pan depicted on the right po-
sition,
as shown above
, respected the flute/groove. Now
replace the pan-like shaped base plate and tighten it softly.
The injection pan should be relatively centered in the mid-
dle of the tube.
Please note:
It is important to place the
side with no holes on the pressure nozzle of the pump,
rather than the side with holes.
Next, pull the silicone tube through the tube, with one end
attached to the nozzle and the other to the si lencer. Finally,
check the silencer.
The upper cover is only loosely stuck on and should be
easy to remove. If this is not the case, insert a screw driver
from the bottom side of the 10 mm air tube and gently hit
the cover. The cover should then be easy to remove and
the silencer becomes accessible.
Replace the cover after cleaning. Please do not insert cot-
ton wool or activated carbon into the silencer. We explicitly
point out that the pump cannot be operated in dry run.
The pump may under no circumstances be operated on a
dry run, even for testing purposes. Doing so may result in
instant damage.
As a last step, reassemble the red suction tube with the
nozzle and ensure tight fit, connect air hose. The skimmer
is now operational again.
5. Power outages and emergency power supply
After a blackout the pump will start automatically and the
controller will set up the last chosen speed.
The pump can used on a commercial emergency power
supply or a commercial UPS, which is fitted with a rectifier
package.